- Metal enclosure
Ordering data
Product type description | TESK-SA-12ST2 |
Article number (order number) | 103005748 |
EAN (European Article Number) | 4030661447476 |
eCl@ss number, Version 9.0 | 27-27-06-09 |
eCl@ss number, Version 11.0 | 27-27-06-09 |
ETIM number, version 6.0 | EC002591 |
ETIM number, version 7.0 | EC002591 |
Approval - Standards
Certificates | cULus CCC EAC |
General data
Enclosure material | Zinc die-cast |
Material of the contacts, electrical | Silver-nickel alloy 10 |
Colour of the housing | Silver |
Gross weight | 328 g |
General data - Features
Mounting inside | No |
Mounting outside | Yes |
Adjustable switching angle | No |
Alignment aid | Yes |
Number of auxiliary contacts | 1 |
Number of safety contacts | 2 |
Safety appraisal
Standards | BG-GS-ET-15 EN ISO 13849-1 EN 60947-5-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
B10d Normally open contact (NO) | 1,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Mechanical data - Connection technique
Terminal Connector | Connector M12 |
Mechanical data - Dimensions
Length of sensor | 20 mm |
Width of sensor | 78 mm |
Height of sensor | 116 mm |
Ambient conditions
Degree of protection | IP65 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +65 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 30 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
Electrical data
Thermal test current | 2.5 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | NO contact, NC contact |
Switching principle | Creep circuit element |
Switching frequency | 1,200 /h |
Наш менеджер свяжется с вами в ближайшее время