- Protection field height 800 mm
- 3-beam
- Safety type 4 in accordance with IEC 61496-1
- Integrated AS-Interface
- Range 0,3 … 12
- Configurable blanking functions
- Integrated status indicator
Ordering data
Product type description | SLG440AS-ER-0800-03 |
Article number (order number) | 103007554 |
EAN (European Article Number) | 4030661449364 |
eCl@ss number, Version 9.0 | 27-27-27-03 |
eCl@ss number, Version 11.0 | 27-27-27-03 |
Approval - Standards
Certificates | TÜV cULus ASi-SaW EAC |
General data
Standards | EN 50295 EN 62061 EN 61496-1 CLC/TS 61496-2 EN ISO 13849-1 |
Active principle | optoelectronic |
Enclosure material | Aluminium |
Beam distance | 400 mm |
Gross weight | 1,480 g |
Reaction time, maximum | 18 ms |
General data - Features
Safety functions | Yes |
Hide function | Yes |
7-segment display | Yes |
Integral System Diagnostics, status | Yes |
Number of beams | 3 |
Safety appraisal
Standards | EN 62061 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 5.17 x 10⁻⁹ /h | |
| 3 | |
Mission Time | 20 Year(s) | |
Safety type in accordance with IEC 61496-1 | 4 |
Mechanical data
Detection ability for test bodies at v = 1.6 m/s | 400 mm |
Range, protection field, minimum | 300 mm |
Range, protection field, maximum | 12,000 mm |
Wave length of the sensor | 880 nm |
Mechanical data - Connection technique
Terminal Connector | Connector |
Terminal connector, Recipient | Connector plug M12, 5-pole |
Terminal, Connector, Transmitter | Connector plug M12, 4-pole |
Mechanical data - Dimensions
Height of Receiver | 963 mm |
Length of sensor | 33 mm |
Width of sensor | 27.8 mm |
Height of the Sensor (Transmitter) | 943 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -10 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 0.35 mm |
Restistance to shock | 10 g / 16 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 2 |
Electrical data - AS Interface
AS-i Operating voltage, minimum | 18 VDC |
AS-i Operating voltage AS-i maximum | 31.6 VDC |
Note (AS-i Operating voltage) | Protection against polarity reversal |
AS-i Current consumption, maximum | 50 mA |
Electrical data - AS-Interface specification
AS-i Specification | Safety-Slave |
AS-i Version | V 3.0 |
AS-i Profile | S-0.B.F.E |
AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
AS-i Outputs, DO 0 … DO 3 | No Function |
AS-i Parameter bits, P0 | No function |
AS-i Parameter bits, P1 | Low beam quality |
AS-i Parameter bits, P2 | No function |
AS-i Parameter bits, P3 | Internal device error (FID) |
Note (AS-i Parameter bits) | Set the parameter outputs to '1111' (0xF) FID: periphery error |
AS-i Input module address | 0 |
Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Electrical data - Auxiliary voltage
Rated operating voltage | 24 VDC -15% / +10% (stabilised PELV) |
Power consumption, Receiver | 150 mA |
Power consumption, Transmitter | 75 mA |
Status indication
Note (LED switching conditions display) | Green/red LED (AS-i duo LED): Supply voltage / communication error / slave address = 0 / periphery error detected |