- Memory card
- Expandable with safe remote IO modules
- Safe cross communication between up to 4 master controllers
- Device in safety fieldbus networks
- integrated SD-Bus-Gateway
- Modularly expandable to up to 272 safe inputs / outputs
- Safe spindle monitoring To EN 61800-5-2 (Safe Drive Monitoring) for up to 12 spindles
- 4 safe 2 A pp-switching semiconductor outputs, switchable to 2 safe p- / n-switching semiconductor outputs
- 14 safe inputs on the base module
- 20 switchable, safe inputs / outputs
- 6 Signalling outputs
- 2 safety relay contacts
Ordering data
Note (Delivery capacity) | Coming soon. |
Product type description | PSC1-C-100-FB1-ECFS |
Article number (order number) | 103011997 |
EAN (European Article Number) | 4030661480992 |
eCl@ss number, Version 9.0 | 27-24-22-07 |
eCl@ss number, Version 11.0 | 27-24-22-07 |
ETIM number, version 6.0 | EC000236 |
Approval - Standards
Certificates | TÜV cULus EAC |
General data
Terminal (mechanical) | Removable screw terminals |
Gross weight | 970 g |
General data - Features
SD Card Slot | Yes |
Master-Slave-Kommunikation | Yes |
Master-Master-Kommunikation | Yes |
Integrated SD gateway | Yes |
Number of pulse outputs (test pulse output) | 6 |
Number of relay outputs (1-channel) | 2 |
Number of digital fail-safe inputs | 14 |
Number of digital fail-safe in-/outputs | 20 |
Number of fail-safe digital outputs | 4 |
Number of signalling outputs | 6 |
Anzahl der Erweiterungsbaugruppen, maximal | 8 |
Safety appraisal
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 1.22 x 10⁻⁸ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Mounting | can be clipped into standard rail |
Mechanical data - Connection technique
Cable section, minimum | 0.2 mm² |
Cable section, maximum | 2.5 mm² |
Wire cross-section, minimum | 24 AWG |
Wire cross-section, maximum | 12 AWG |
Mechanical data - Dimensions
Width | 112.5 mm |
Height | 100 mm |
Depth | 115 mm |
Ambient conditions
Degree of protection | IP20 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Relative humidity, minimum | 5 % |
Relative humidity, maximum | 85 % |
Note (Relative humidity) | non-condensing |
Zulässige Aufstellhöhe über NN, maximum | 2,000 m |
Ambient conditions - Insulation value
Overvoltage category | III |
Degree of pollution to IEC/EN 60664-1 | 2 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 28.8 VDC |
Electrical data - Universal communication interface
Designation, Communication interface | RJ45 |
Electrical data - Communication protocols
Field bus | EtherCAT EtherNet IP PROFINET IO EtherCAT / FSoE |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 2,000 mA |
Versions | short-circuit proof, p-type (Q2 und Q3) |
Electrical data - Safe relay outputs
Voltage, Utilisation category AC15 | 230 VAC |
Current, Utilisation category AC-15 | 2 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 2 A |
Electrical data - Electromagnetic compatibility (EMC)
Electromagnetic compatibility | DIN EN 62061 DIN EN 61800-3 |
Interfering radiation | DIN EN 61000-6-4 |
EMC rating | DIN EN 61000-6-7 DIN EN 61326-3 DIN EN 61000-6-2 |
Scope of delivery
Included in delivery | Backplane bus connector Connector terminals |