- Repeated individual coding with RFID technology
- Power to unlock
- Guard locking monitored
- Thermoplastic enclosure
- Max. length of the sensor chain 200 m
- Self-monitoring series-wiring
- Coding in accordance to ISO 14119 by using RFID-Technology
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Suitable for hinged and sliding guards
- Intelligent diagnosis
- Manual release
- Protection class IP66, IP67
- High holding force 2000
- symmetrical construction form, assembly on 40mm profiles
- OSSD safety outputs
- Emergency exit / Emergency release suitable for retrofitting
Ordering data
Product type description | AZM201Z-I2-ST2-T-SD2P |
Article number (order number) | 103013492 |
EAN (European Article Number) | 4030661493350 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
eCl@ss number, Version 11.0 | 27-27-26-03 |
Approval - Standards
Certificates | TÜV cULus EAC FCC IC |
General data
Standards | IEC 60947-5-1 EN ISO 13849-1 IEC 61508 IEC 60947-5-3 EN ISO 14119 IEC 62061 | |
general information | Individual coding, multiple teaching | |
Coding level according to ISO 14119 | High | |
Active principle | RFID | |
Enclosure material | Glass-fibre, reinforced thermoplastic | |
Gross weight | 595 g | |
Time to readiness, maximum | 4,000 ms | |
Duration of risk, maximum | 200 ms | |
| 100 ms | |
| 0.5 ms |
General data - Features
Power to unlock | Yes |
Guard locking monitored | Yes |
Serial diagnostics | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of safety contacts | 2 |
Number of Series-wiring of sensors | 31 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 62061 IEC 61508 |
Safety appraisal - Interlocking
Performance level, up to | e |
Control category | 4 |
PFH-value | 1.90 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Safety appraisal - Guard locking
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Clamping force in accordance with ISO14119 Fzh | 2,000 N |
Clamping force, maximum Fmax | 2,600 N |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Mechanical data - Connection technique
Terminal Connector | Connector M12, 8-pole |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Ambient conditions
Degree of protection | IP66 to EN 60529 IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +60 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Operating voltage, minimum | 20.4 VDC |
Operating voltage, maximum | 26.4 VDC |
No-load supply current I0 | 50 mA |
Current consumption with solenoid ON, average | 200 mA |
Current consumption with solenoid ON, peak | 700 mA / 100 ms |
Operating current | 1,200 mA |
Switching frequency, approx. | 1 Hz |
Electrical data - Solenoid control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 4 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic output
Operating current | 50 mA |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT serial diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN serial diagnostic input |
Scope of delivery
Included in delivery | Actuators must be ordered separately. Triangular key for AZM 201 |
Accessory
Recommendation (actuator) | AZ/AZM201-B1 AZ/AZM201-B30 |
Notes
Note (General) | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |