- integrated FB interface for connection to the Safety-Field-Box SFB
- Pos 1: E-STOP with protective collar
- Pos 2: Key selector switch, 2 positions
- Pos 3: Selector switch, 3 positions
- Pos 4: WHITE illuminated pushbutton
- Indicator lamp G24 on top
- slender shock-proof thermoplastic enclosure
- to be installed at an ergonomic favourable position
- to be fitted to commercial-off-the-shelf aluminium profiles
- E-STOP with electronic OSSDs
Ordering data
Product type description | BDF200-FB-NHK-SWS20-WS30-LTWH-G24 |
Article number (order number) | 103015449 |
EAN (European Article Number) | 4030661509662 |
eCl@ss number, Version 9.0 | 27-33-02-04 |
eCl@ss number, Version 11.0 | 27-33-02-04 |
ETIM number, version 6.0 | EC001415 |
Approval - Standards
Certificates | TÜV cULus EAC |
General data
Standards | IEC 60947-5-1 EN ISO 13849-1 IEC 61508 IEC 60947-5-5 ISO 13850 | |
Climatic stress | IEC 60947-5-5 | |
Terminal (mechanical) | Connector plug M12, 8-pole, A-coded | |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | |
Gross weight | 280 g | |
Reaction time, maximum | 50 ms | |
Duration of risk, maximum | 100 ms | |
Positions used, position 1 | Emergency stop, with protective collar | |
Positions used, position 2 |
| |
Positions used, position 3 |
| |
Positions used, position 4 | Illuminated pushbutton, white |
General data - Features
Serial diagnostics | No |
Field box interface | YN_FIELDBOX_INTERFACE1 |
Indicator lamp | Yes |
Safety functions | Yes |
Safety appraisal
Standards | EN ISO 13849-1 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 2.89 x 10⁻¹⁰ /h | |
Note (PFH-value) | up to max. 5,000 switching cycles/year | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, Emergency-Stop button | 100,000 Operations |
Mechanical life, Command devices | 1,000,000 Operations |
Mechanical data - Dimensions
Width | 40 mm |
Height | 69 mm |
Length x Width x Height | Depth: 233.5 - 252.5 mm (without and with indicator lamp) |
Ambient conditions
Degree of protection | IP64 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +65 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm / 5 g |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Current consumption at 24V | 5 mA |
No-load supply current I0 | 35 mA |
Rated operating voltage | 24 VDC −15 % / +10 % (PELV to IEC 60204-1) |
Operating current | 150 mA 600 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Utilisation category DC-12 | 24 VDC |
Utilisation category DC-12 | 0.25 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 0.25 A |
Inputs, Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 250 mA |
Voltage drop Ud, maximum | 1 V |
Current leakage Ir | 0.5 mA |
Electrical data - Diagnostic output
Versions | short-circuit proof, p-type |