Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Plug-in spring-cage terminal blocks with coding
  • STOP 0 / 1 Function
  • 1 oder 2-channel control
  • 2 safety contacts STOP 0
  • 1 Safety output STOP 1
  • Drop-out delay 0 … 30

Ordering data

Product type description

SRB-E-212ST-CC

Article number (order number)

103016573

EAN (European Article Number)

4030661510378

General data

Standards

EN 60947-5-1

EN ISO 13849-1

IEC 61508

IEC/EN 60204-1

IEC/EN 62061

Enclosure material

Glass-fibre reinforced thermoplastic, ventilated

Material of the contacts, electrical

Ag-Ni, self-cleaning, positive drive

Gross weight

250 g

General data - Features

Stop-Category

0

1

Wire breakage detection

Yes

Short-circuit recognition

Yes

Removable Terminals

Yes

Start input

Yes

Feedback circuit

Yes

Automatic reset function

Yes

Reset edge detection

Yes

Earth connection detection

Yes

Integral System Diagnostics, status

Yes

Integral System Diagnostics, error code

Yes

Number of LEDs

6

Number of openers

2

Number of shutters

1

Number of Safety contacts, STOP 0

2

Number of fail-safe outputs, Stop 1

1

Number of Signalling outputs, STOP 0

1

Number of Signalling outputs, STOP 1

1

Safety appraisal

Standards

EN ISO 13849-1

IEC 62061

IEC 61508

Safety appraisal - Relay outputs

Performance Level, up to

e

Control category to EN13849

4

Diagnostic Coverage (DC) Level

> 94 %

PFH-value

1.25 x 10⁻⁸ /h

PFD value

5.30 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Common Cause Failure (CCF), minimum

65

Safety appraisal - Fail-safe digital outputs

Performance level, up to

e

Control category to EN13849

4

PFH-value

2.66 x 10⁻⁹ /h

PFD value

2.42 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission time

20 Year(s)

Mechanical data

Mechanical life, minimum

10,000,000 Operations

Mounting

Snaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connector

Spring pulley connection, plug-in

rigid or flexible

Terminal designations

IEC/EN 60947-1

Cable section, minimum

0.25 mm²

Cable section, maximum

1.5 mm²

Mechanical data - Dimensions

Width

22.5 mm

Height

98 mm

Depth

115 mm

Ambient conditions

Degree of protection of the enclosure

IP40

Degree of protection of the mounting space

IP54

Degree of protection of clips or terminals

IP20

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+60 °C

Storage and transport temperature, minimum

-40 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10 ... 55 Hz, Amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Ambient conditions - Insulation value

Rated impulse withstand voltage, relay output Uimp

4 kV

Rated impulse withstand voltage, semiconductor output Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to IEC/EN 60664-1

2

Electrical data

Rated operating voltage

24 VDC -20%/+20%, residual ripple max. 10%

Rated AC voltage for controls at DC minimum

19.2 VDC

Rated control voltage at DC, maximum

28.8 VDC

Electrical power consumption

3 W

Contact resistance, maximum

0.1 Ω

Note (Contact resistance)

in new state

Drop-out delay in case of power failure, typically

10 ms

Drop-out delay in case of emergency, typically

10 ms

Pull-in delay at automatic start, maximum, typically

150 ms

Pull-in delay at RESET, typically

150 ms

Switching frequency, maximum

0.3 Hz

Electrical data - Fail-safe digital outputs

Voltage drop Ud, maximum

0.5 V

Current leakage Ir

1 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

2 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

2 A

Electrical data - Safe relay outputs

Voltage, Utilisation category, AC15

230 VAC

Current, Utilisation category, AC15

4 A

Voltage, Utilisation category, DC13

24 VDC

Current, Utilisation category, DC13

4 A

Switching capacity, minimum

10 VDC

Switching capacity, minimum

10 mA

Switching capacity, maximum

250 VAC

Switching capacity, maximum

6 A

Electrical data - Digital inputs

Conduction resistance, maximum

40 Ω

Electrical data - Digital Output

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.1 A

Electrical data - Electromagnetic compatibility (EMC)

EMC rating

EMC-Directive

Status indication

Indicated operating states

Internal operating voltage Ui

Baustein-Status

Fault codes

Other data

Note (applications)

Safety sensor

hinged safety guard

Emergency-Stop button

Pull-wire emergency stop switches

Safety light curtain

Two-hand control panels

Наш менеджер свяжется с вами в ближайшее время