  • MCD Differential pressuregauge;
  • Nominal size 150 mm;
  • Bottom conn. , wall mounting;
  • G 1/2;
  • without;
  • kPa (EN);
  • 0+1 kPa;
Nominal size
150 mm
Description
Differential pressure gauge
Wetted material
Stainless steel
Accuracy
+/- 2 % F.S.
Measuring range
10 ... 250 mbar
Approvals
GOST
Выберите параметры MCD7-##0.### Заказать
Product
Dimension
Case
Process connection
Damping fluid
UNIT
Measuring range kpa
Housing
Protection rating (EN 60529)
  • IP66
Window material
  • Instrument glass
Window gasket
  • Elastomer
Movement material
  • Brass
Nominal size
  • 150 mm
Case material
  • Stainless steel 1.4301 / AISI 304
Bezel ring material
  • Stainless steel 1.4301 / AISI 304
Dial
  • White, aluminium
Pointer
  • Black, aluminium
Safety
  • Safety valve: Viton - FKM, integrated on the HP side to protect the capsule
Temperature
Ambient temperature
  • -20°C ... +60°C
Storage temperature
  • -40°C ... +70°C
Media temperature
  • -20°C ... +60°C
Wetted parts
Capsule
  • Stainless steel 1.4404 / AISI 316L
Process connection
  • G1/2"
  • 1/2" NPT
Performance
Min. measuring range
  • 0 ... 10 mbar
Max. measuring range
  • 0 ... 250 mbar
Zero adjustment
  • ± 10 % FS
  • Adjustment screw accessible on the front side after removing of bezel ring and window
Overpressure
  • HP side: max. 250 bar
  • LP side: max. 130 % FS
Type of pressure
  • Static pressure: 250 mbar max.
Accuracy
  • ± 2 % FS
Manifolds
  • 3-way manifolds are recommended to ensure to apply the pressure simultaneously on both sides and avoid single-sided overload.
Working principle
  • The HP is applied inside the capsule and the LP outside the capsule (in the case). The deflection of the capsule results from the difference between the pressure inside (HP) and outside (LP)
Weight
Gauge
  • 900 g