Analog output / redundant
- Magnetic sensing method
- Resolution: 12 bit
- Interface analog 0...10 V / 0.5…4.5 V / 4...20 mA
- Measuring length up to 5 m
- Removable cabs for water outlet
- Teach inputs
- Extremely light thanks to housing of plastic and aluminium
- Available with redundant absolute signals
Technical data - electrical ratings
- Voltage supply
- 8...30 VDC
- Reverse polarity protection
- Yes
- Short-circuit proof
- Yes
- Consumption typ.
- 35 mA (24 VDC, w/o load)
- Initializing time
- ≤500 ms after power on
- Response time
- < 1 ms
- Interface
- Analog 0...10 V / 0.5...4.5 V / 4...20 mA / Resolution: 12 bit
- Function
- Linear position feedback
- Linearity
- ±0.65 % full scale output (f.s.o.)
- Absolute accuracy
- ±1,13 % f.s.o. (+25 °C)
- ±1,41 % f.s.o. (-40...+85 °C)
- Sensing method
- Magnetic
- Repeatability typ.
- 5 mm
- Interference immunity
- DIN EN 61000-6-2
- Emitted interference
- DIN EN 61000-6-4
- Programmable parameters
- Measuring range teachable
- Diagnostic function
- Self-diagnosis
- Reading back voltage output
- Factory setting
- Entire measuring range Min. output at 0 m Max. output at 5 m
Technical data - mechanical design
- Protection DIN EN 60529
- IP 65 (encoder)
- Material
- Encoder housing: aluminium
- Cable-pull housing: PA6 GF30
- Cable: Stainless steel cable coated with polyamide
- Operating temperature
- -40...+85 °C
- Service life
- Typ. >500000 strokes
- Measuring length
- 5 m
- Cable acceleration
- ≤50 m/s²
- Cable diameter
- 0,61 mm
- Pull-in force
- >3 N
- Pull-out force
- ≤9 N
- Relative humidity
- 95 % temporary condensing
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz
- DIN EN 60068-2-27 Shock 50 g, 11 ms
- Weight approx.
- 400 g
- Connection
- Flange connector M12, 5-pin
- Flange connector M12, 8-pin
- Cable 2 m
- Bending radius
- Cable: >55 mm
- Special characteristics
- Coated electronic
- Instruction
- Please consider the assembly instructions
Baumer_BMMSK50_analog_DS_EN.pdf
Baumer_BMMS_DE_EN_FR_CoC_81162933.pdf
Baumer_BMMS_K_M_Analog_II_A4_DE_EN_FR_IT_ES_81195324.pdf
Baumer_cable_transducer_BR_EN_1709_11191945_LRes.pdf
Baumer_BMMS_DE_EN_FR_CoC_81162933.pdf
Baumer_BMMS_K_M_Analog_II_A4_DE_EN_FR_IT_ES_81195324.pdf
Baumer_cable_transducer_BR_EN_1709_11191945_LRes.pdf
Наш менеджер свяжется с вами в ближайшее время