Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Cable transducer - absoluteAnalog output
- Analog interface
- Magnetic sensing
- Operating temperature -40...+85 °C
- Protection IP 67
- Flange connector M12 or cable
- Measuring length 2.3 m and 4.7 m
- Designed for harsh environmental conditions
- Removable stickers for drainage
Technical data - electrical ratings
- Voltage supply
- 8...30 VDC
- 12...30 VDC
- Reverse polarity protection
- Yes
- Short-circuit proof
- Yes
- Consumption typ.
- 30 mA (24 VDC, w/o load, current output)
- 10 mA (24 VDC, w/o load, voltage output)
- Initializing time
- ≤500 ms after power on
- Interface
- Analog 0...10 V / 0.5...4.5 V / 4...20 mA
- Load resistor
- Between Out/0 V ≥3 kΩ / voltage output
- 270 Ω at 10 VDC (500 Ω at 15 VDC) / current output
- Function
- Linear position feedback
- Resolution
- 12 bit
- Linearity
- ±1 % FS
- Absolute accuracy
- ±1,8 % FS (+25 °C)
- ±% FS (-40...+85 °C)
- Sensing method
- Magnetic
- Interference immunity
- DIN EN 61000-6-2
- Emitted interference
- DIN EN 61000-6-3
Technical data - mechanical design
- Protection DIN EN 60529
- IP 67 (housing, drainage holes closed)
- IP 54 (cable inlet)
- Material
- Cable: Stainless steel cable AISI 316 coated with nylon PA12
- Housing: plastic
- Operating temperature
- -40...+85 °C
- Measuring length
- 2,3 m
- 4,7 m
- Cable diameter
- 0,9 mm
- Cable fastening
- Eyelet Height: 5 mm Internal diameter: 8 mm Outer diameter: 15 mm
- Pull-in force
- >1,5 N (pull-in force reduced at low temperatures)
- Pull-out force
- ≤8 N
- Relative humidity
- 95 % non-condensing
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 10-2000 Hz
- DIN EN 60068-2-27 Shock 50 g, 11 ms
- Weight approx.
- 625 g
- Connection
- Cable 2 m, radial
- Flange connector M12, 5-pin
- Flange connector M12, 8-pin
- Instruction
- Please consider the assembly instructions
Baumer_GCA5-Analog_II_A4_DE_EN_81197555.pdf
Baumer_GCA5-PM047_RAN_xx0_A_stp_CAD.zip
Baumer_GCA5_analog_DS_EN.pdf
Baumer_GCA_BR_EN_1806_11203336_LRes.pdf
Baumer_GCA5-PM047_RAN_xx0_A_stp_CAD.zip
Baumer_GCA5_analog_DS_EN.pdf
Baumer_GCA_BR_EN_1806_11203336_LRes.pdf
Наш менеджер свяжется с вами в ближайшее время