Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Speed switchesSafety motion monitor with SIL3 and PLe certification
- SIL3 and PLe certification
- Monitoring of underspeed, overspeed, standstill and rotating direction
- Inputs for HTL/RS422/SinCos encoders and sensors
- Safety related outputs and signal splitter
- Mounting to 35 mm DIN rail (according to EN 60715)
- USB interface for simple parametrization by the OS 6.0 operator surface
Safety-relevant key characteristics
- DCavg (ISO 13849)
- 97,95 %
- Category (ISO 13849)
- 3 (HFT = 1)
- Classification
- SIL3/PLe (depending on the used encoder input signals)
- MTTFd (ISO 13849)
- 38.1 years
- PFH (IEC 61508 / EN 62061)
- 3,76 * 10 -8h -1
- SFF
- 98,77 %
- Safety functions
- Equivalent to EN 61800-5-2 for SS1, SS2, SOS, SLS, SDl, SSM, SLI, SBC, STO, SMS (depending on the used encoder input signals)
- Structure
- Dual-channel
- Service interval
- Switch on/off for at least 1 times a year (at continuous operation)
- λDD / λDU
- 2,94 * 10-6 h-1 / 6,14 * 10-8 h-1
- λSD / λSU
- 1,93 * 10-6 h-1 / 4,64 * 10-8 h-1
Technical data - electrical ratings
- Input voltage
- 18...30 VDC
- Consumption w/o load
- ~150 mA
- Protective circuit input
- Reverse polarity protection, external fuse (2.5 A, medium time-lag) necessary
- Residual ripple
- ≤10 % (24 VDC)
- Encoder output voltage
- ~2 VDC less the input voltage
- Protective circuit encoder supply
- Short-circuit-proof
- Encoder output current
- ≤200 mA each encoder
- Inputs
- 2x SinCos encoder
- 2x RS422 incremental encoder
- 2x HTL/PNP incremental encoders, proximity switches or control signals
- Outputs (safety related)
- 1x relay output 5...36 VDC (NO)
- 1x analogue output 4...20 mA
- 4x control output HTL
- Signal splitter (safety related)
- 1x SinCos splitter output
- 1x RS422 splitter output
- Status indicator
- LEDs
- Control functions
- DIL switch: 1 x 3-pin
- LED operating status
- Green = ready for use "ON"
- Yellow = "ERROR"
- Interference immunity
- EN 61000-6-2; EN 61326-3-2
- Emitted interference
- EN 61000-6-3; EN 61000-6-4
- Approval
- CE
- SIL3/PLe EN ISO 13849-1, EN 61508, EN 62061
Technical data - mechanical design
- Dimensions (W x H x D)
- 50 x 100 (120) x 165 mm
- With programming unit GMI230S: 50 x 100 (120) x 180 mm
- Protection DIN EN 60529
- IP 20
- Operating temperature
- -20...+55 °C (without dew)
- Storage temperature
- -25...+70 °C (without dew)
- Weight approx.
- 390 g
- Mounting type
- 35 mm DIN rail (according to EN 60715)
- Connection
- Plug-in screw terminal 1.5 mm2
- Connector D-SUB, female, 9-pin (SinCos input)
- Connector D-SUB, female, 9-pin (SinCos output)
- USB 1.0 / type B (female)
- Material
- Plastic
Baumer_GMM230S_DS_EN.pdf
Baumer_GMM2xxS-SIL3_CA_DE-EN.pdf
Baumer_GMMxxxS_SIL_DE-EN-FR_CoC_81241214.pdf
Shielding_instruction_Baumer_GMM2xxS.pdf
Baumer_GMM2xxS-SIL3_CA_DE-EN.pdf
Baumer_GMMxxxS_SIL_DE-EN-FR_CoC_81241214.pdf
Shielding_instruction_Baumer_GMM2xxS.pdf
Наш менеджер свяжется с вами в ближайшее время