Absolute encodersSolid shaft with clamping flange
- Encoder single- or multiturn / CANopen® redundant
- Redundant sensing with galvanical separation
- ISO 13849 compliant firmware
- Resolution max. 32 bit (14 bit ST, 18 bit MT)
- E1 compliant design
- High protection IP 67
- High resistance to shock and vibrations
- Protection against corrosion C5-M
- Wire cross section 0.5 mm²
Technical data - electrical ratings
- Voltage supply
- 10...30 VDC
- Consumption typ.
- 35 mA (24 VDC, w/o load)
- Initializing time
- ≤170 ms after power on
- Interface
- CANopen®
- Function
- Multiturn
- Singleturn
- Profile conformity
- CANopen® CiA communication profile DS 301, LSS profile DSP 305, device profile DS 406
- Steps per revolution
- ≤16384 / 14 bit
- Number of revolutions
- ≤262144 / 18 bit
- Absolute accuracy
- ±0,15 ° (+20 ±15 °C)
- ±0,25 ° (-40...+85 °C)
- Sensing method
- Magnetic
- Code sequence
- CW: ascending values with clockwise sense of rotation; looking at flange
- Output stages
- CAN-Bus, LV (3.3 V) compatible ISO 11898
- Interference immunity
- DIN EN 61000-6-2
- ISO 11452-2:2004* / -5:2002*
- ISO 7637-2:2004*
- ISO 10605:2008 + Amd 1:2014 (CD ±8 kV / AD ±15 kV)
- * Severity level according to ECE R10 (Rev. 4)
- Emitted interference
- DIN EN 61000-6-4 CISPR 25:2008 (30..1000 MHz)
- ISO 7637-2:2004*
- * Severity level according to ECE R10 (Rev. 4)
Technical data - mechanical design
- Size (flange)
- ø58 mm
- Shaft type
- ø10 x 20 mm, solid shaft with flat
- Flange
- Clamping flange
- Protection DIN EN 60529
- IP 67 (with shaft seal)
- Operating speed
- ≤6000 rpm
- Starting torque
- ≤2,5 Ncm (+20 °C, IP 67)
- Moment of inertia
- 15,38 gcm²
- Admitted shaft load
- ≤40 N axial
- ≤80 N radial
- Material
- Housing: steel, powder-coated
- Flange: aluminium
- Shaft: stainless steel
- Corrosion protection
- IEC 60068-2-52 Salt mist
- for ambient conditions CX (C5-M) according to ISO 12944-2
- Operating temperature
- -40...+85 °C (see general information)
- Relative humidity
- 95 %
- Resistance
- DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz
- DIN EN 60068-2-27 Shock 500 g, 1 ms
- Weight approx.
- 250 g
- Connection
- Flange connector M12, 5-pin
- Cable 2 m
- Instruction
- Use in safety functions exclusively based on Application Note and MTTFd reliability prediction (request separately).
Baumer_EAM580-SC0_7LC8_xxxxx_A-stp_CAD.zip
Baumer_EAM580R_CANopen_red_II_A4_DE_EN_FR_IT_ES_81239877.pdf
Baumer_EAM580R_solid_shaft_clamping_flange_CANopen_redundant_DS_EN.pdf
Baumer_EAM580_360_CANopen_MA_EN_Rev0003_0000h_Index0004.pdf
Baumer_EAM580_DE-EN-FR_CoC_81240035.pdf
Baumer_EAM580_EAM360_BR_EN_1806_11202518_LRes.pdf
Baumer_EAMxxx_EDS_file_SW.zip
Baumer_EAM580R_CANopen_red_II_A4_DE_EN_FR_IT_ES_81239877.pdf
Baumer_EAM580R_solid_shaft_clamping_flange_CANopen_redundant_DS_EN.pdf
Baumer_EAM580_360_CANopen_MA_EN_Rev0003_0000h_Index0004.pdf
Baumer_EAM580_DE-EN-FR_CoC_81240035.pdf
Baumer_EAM580_EAM360_BR_EN_1806_11202518_LRes.pdf
Baumer_EAMxxx_EDS_file_SW.zip
Наш менеджер свяжется с вами в ближайшее время