Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Absolute encodersEx approval Ex II 2D/2G (ATEX)
- Encoder multiturn / Profibus / ATEX
- Optical sensing method
- Resolution: singleturn 13 bit, multiturn 16 bit
- Clamping flange with solid shaft ø10 mm
- Explosion protection per Ex II 2D/2G (ATEX)
- Device class 2 / zone 1 (gas), zone 21 (dust)
- Maximum resistant against magnetic fields
Technical data - electrical ratings
- Voltage supply
- 10...30 VDC
- Reverse polarity protection
- Yes
- Consumption w/o load
- ≤100 mA (24 VDC)
- Initializing time typ.
- 250 ms after power on
- Interface
- Profibus-DPV0
- Function
- Multiturn
- Device adress
- Rotary switches in bus cover
- Steps per revolution
- ≤8192 / 13 bit
- Number of revolutions
- ≤65536 / 16 bit
- Absolute accuracy
- ±0,025 °
- Sensing method
- Optical
- Code
- Binary
- Code sequence
- CW/CCW programmable
- Interference immunity
- DIN EN 61000-6-2
- Emitted interference
- DIN EN 61000-6-4
- Programmable parameters
- Operating modes
- Total resolution
- Scaling
- Rotation speed monitoring
- Diagnostic function
- Position or parameter error
- Multiturn sensing
Technical data - mechanical design
- Size (flange)
- ø70 mm
- Shaft type
- ø10 mm solid shaft (clamping flange)
- Flange
- Clamping flange
- Protection DIN EN 60529
- IP 67
- Operating speed
- ≤6000 rpm (mechanical)
- ≤6000 rpm (electric)
- Starting acceleration
- ≤1000 U/s²
- Starting torque
- ≤0,4 Nm (+25 °C)
- Admitted shaft load
- ≤60 N axial
- ≤50 N radial
- Material
- Housing: stainless steel
- Flange: stainless steel
- Operating temperature
- -20...+70 °C
- Relative humidity
- 95 % non-condensing
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz
- DIN EN 60068-2-27 Shock 200 g, 6 ms
- Explosion protection
- Ex II 2G Ex d IIC T6
- Ex II 2D
- Weight approx.
- 1500 g
- Connection
- Bus cover
Наш менеджер свяжется с вами в ближайшее время