Technical data — electrical ratings | |
---|---|
Voltage supply | 5 VDC ±10 % 10…30 VDC |
Consumption typ. | 30 mA (5 VDC, w/o load) 15 mA (24 VDC, w/o load) |
Pulses per revolution | 64…2048 |
Reference signal | Zero pulse, width 90° |
Sensing method | Magnetic |
Output frequency | 320 kHz |
Output signals | A 90° B, N + inverted |
Output stages | Antivalent Push-pull short-circuit proof |
Interference immunity | DIN EN 61000-6-2 |
Emitted interference | DIN EN 61000-6-3 |
Approval | UL approval / E217823 |
Technical data — mechanical design | |
Size (flange) | 58 mm |
Shaft type | 6 mm solid shaft (synchro flange) |
Shaft loading | 40 N axial 50 N radial |
Flange | Synchro flange |
Protection DIN EN 60529 | IP 42 IP 65 |
Operating speed | 12000 rpm (IP 42) 6000 rpm (IP 65) |
Operating torque typ. | 0.0175 Nm (IP 42) 0.047 Nm (IP 65) |
Materials | Housing: aluminium Flange: aluminium |
Operating temperature | -20…+85 °C |
Relative humidity | 95 % non-condensing |
Resistance | DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 500 g, 6 ms |
Connection | Connector M12, 5-pin Connector M12, 8-pin Connector M23, 12-pin Cable 2 m |
Weight approx. | 150 g |
Наш менеджер свяжется с вами в ближайшее время