Technical data — electrical ratings | |
---|---|
Voltage supply | 24/110 VAC ±10 % (50/60 Hz) 230 VAC +6/-10 % (50/60 Hz) 12/24 VDC ±10 % |
Residual ripple | |
Nominal frequency | 50 / 60 Hz |
Power consumption | 1.8 W 2 VA |
Pulse ratio | 1:1 |
Service life | 10 million impulses |
Standard DIN EN 61010 1 |
Protection class II Overvoltage category II Pollution degree 2 |
Emitted interference | DIN EN 61000-6-4 |
Interference immunity | DIN EN 61000-6-2 |
Technical data — mechanical design | |
Display | White numbers on black |
Number of digits | 5-digits with reset button 7-digits without reset button |
Digit height | 4 mm |
Count mode | 1 impulse = 1 count |
Step-by-step switching | Adding in 2 half steps |
Measuring range | 99 999 and 9 999 999 |
Zero setting | Manual by reset button |
Ambient temperature | 0…+45 °C |
Storage temperature | -20…+70 °C |
Relative humidity | 80 % non-condensing |
Protection DIN EN 60529 | IP 41 |
Housing type | Built-in housing |
Connection | Stranded wires, 300 mm long |
Mounting | Rear center screw mount |
Dimensions W x H x L | 36 x 22 x 45 mm |
Cutout dimensions | 36 x 22 mm |
Mounting depth | 55 mm |
Weight approx. | 50 g |
Material | Housing: Noryl PPO, black |