  • Protection class IP67
  • Safety type 4 in accordance with IEC 61496-1
  • Resolution 14, 30 and 50 mm
  • Protection field height from 170 mm … 1770 mm

Ordering data

Product type description

SLC 420-E/R0170-14-RFBM

Article number (order number)

101206843

eCl@ss number, Version 9.0

27-27-27-04

eCl@ss number, Version 11.0

27-27-27-04

Approval - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

IEC/EN 61496-1/-2

Master- or Slave-function

master

Enclosure material

Aluminium

Gross weight

1,310 g

Reaction time, maximum

10 ms

General data - Features

Cascadable

Yes

Restart interlock (manual reset)

Yes

Beam coding available

Yes

Hide function

Yes

Integral System Diagnostics, status

Yes

Integral System Diagnostics

Yes

Number of beams

16

Number of fail-safe digital outputs

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

6.19 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Safety type in accordance with IEC 61496-1

4

Mechanical data

Detection ability for test bodies at v = 1.6 m/s

14 mm

Height of the protection field

170 mm

Range, protection field, minimum

300 mm

Range, protection field, maximum

7,000 mm

Wave length of the sensor

880 nm

Mechanical data - Connection technique

Terminal Connector

Connector

Terminal connector, Recipient

Connector plug M12, 8-pole

Terminal, Connector, Transmitter

Connector plug M12, 4-pole

Length of the connectable cable, maximum

100 m

Mechanical data - Dimensions

Diameter of sensor

49 mm

Height of sensor

255 mm

Ambient conditions

Degree of protection

IP67 to EN 60529

Ambient temperature, minimum

-10 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+70 °C

Protection rating

III

Electrical data

Voltage type

DC (direct current)

Switching voltage OSSD, HIGH signal

24 V

Electrical power consumption of the receiver

8 W

Electrical power consumption of the transmitter

4 W

Cable length (Master/Slave), maximum

3 m

Electrical data - Fail-safe digital outputs

Output current, (fail-safe output), maximum

0.5 A

Versions

p-type

Scope of delivery

Included in delivery

Kit with 2 mounting angles

Accessory

Recommended safety switchgear

SRB-E 301

Notes

Note (General)

Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA.