        - Design M 18 x 1
Ordering data
| Product type description | IFL 5-18-11ZSTPK-1952-2 | 
| Article number (order number) | 101102130 | 
| EAN (European Article Number) | 4030661022468 | 
| eCl@ss number, Version 9.0 | 27-27-01-01 | 
| eCl@ss number, Version 11.0 | 27-27-01-01 | 
| ETIM number, version 6.0 | EC002714 | 
| ETIM number, version 7.0 | EC002714 | 
General data
| Standards | IEC/EN 60947-5-2 DIN VDE 0660-208 | 
| Housing construction form | Cylinder, thread | 
| Installation conditions (mechanical) | flush | 
| Enclosure material | Brass | 
| Enclosure coating material | nickel-plated | 
| Active area | Plastic | 
| Material of the nuts | Brass | 
| Gross weight | 255 g | 
General data - Features
| Integral System Diagnostics, status | Yes | 
| Number of cable wires | 4 | 
Mechanical data
| Tightening torque of nuts, maximum | 18 Nm | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 5 mm | 
Mechanical data - Connection technique
| Terminal Connector | REVIEW_ELEC_DATA_WIRING_GENERALFMAW00000001 | 
Mechanical data - Dimensions
| ISO thread of the sensor | M18 | 
| width across flats | 24 BK | 
Ambient conditions
| Degree of protection | IP67 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +110 °C | 
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm | 
| Restistance to shock | 30 g / 11 ms | 
| Protection rating | 0 | 
Electrical data
| Operating voltage, minimum | 10 V | 
| Operating voltage, maximum | 60 V | 
| No-load supply current I0 | 4.8 mA | 
| Operating current | 100 mA | 
| Switching element | NO contact and NC contact (antivalent) | 
| Protection circuit integrated | Protection against polarity reversal Surge protection Max. fuse rating | 
| Switching frequency, approx. | 500 Hz | 
Electrical data - Digital Output
| Voltage drop Ud, maximum | 1.5 V | 
| Current at Voltage drop Ud | 0.4 A | 
| Versions | p-type | 
Status indication
| Note (Integral System Diagnostics, status ) | yellow LED | 