- 2 cable entries M 20 x 1.5
- Metal enclosure
- 2 Contacts
- 106 mm x 99 mm x 63 mm (basic component)
- Protection class IP65
Ordering data
| Product type description | TS 441-11Y |
| Article number (order number) | 101058348 |
| EAN (European Article Number) | 4030661032177 |
| eCl@ss number, Version 9.0 | 27-27-06-01 |
| eCl@ss number, Version 11.0 | 27-27-06-01 |
| ETIM number, version 6.0 | EC000030 |
| ETIM number, version 7.0 | EC000030 |
Approval - Standards
| Certificates | DNV.GL CCC EAC |
General data
| Standards | EN 60947-5-1 |
| Active principle | mechanical |
| Slide form | Sphere |
| Enclosure material | Grey cast iron, galvanised |
| Enclosure coating material | painted |
| Material of the contacts, electrical | Silver |
| Gross weight | 1,245 g |
General data - Features
| Number of openers | 1 |
| Number of shutters | 1 |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
| Actuating element | Plunger |
| Mechanical life, minimum | 10,000,000 Operations |
| Actuating angle | 20 ° |
| Contact opening | 2 x 6 mm |
| Actuating speed, minimum | 1 mm/min |
| Actuating speed, maximum | 1 m/s |
| Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable section, minimum | 1.5 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Wire cross-section | 13 AWG |
Mechanical data - Dimensions
| Length of sensor | 63 mm |
| Width of sensor | 106 mm |
| Height of sensor | 125 mm |
| Diameter of the Plunger | 10 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 |
| Ambient temperature, minimum | -30 °C |
| Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 400 V |
| Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
| Thermal test current | 16 A |
| Utilisation category AC-15 | 400 VAC |
| Utilisation category AC-15 | 4 A |
| Switching element | NO contact, NC contact |
| Note (Switching element) | with double break |
| Switching principle | Creep circuit element |
Notes
| Note (General) | Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. |