- Metal enclosure
- 58 mm x 142 mm x 61,5 mm (basic component)
- operating shaft with ball bearings
- 3 Cable entry M 20 x 1.5
- Protection class IP67
- Actuator head can be repositioned in steps 4 x 90°
Ordering data
Product type description | M2L 035-11Z-M20 |
Article number (order number) | 101161651 |
EAN (European Article Number) | 4030661196244 |
eCl@ss number, Version 9.0 | 27-27-06-01 |
eCl@ss number, Version 11.0 | 27-27-06-01 |
ETIM number, version 6.0 | EC000030 |
ETIM number, version 7.0 | EC000030 |
Approval - Standards
Certificates | CCC EAC |
General data
Standards | EN 60947-5-1 |
Active principle | mechanical |
Slide form | Castor |
Enclosure material | Grey cast iron, galvanised |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Roller material | Metal film |
Gross weight | 1,715 g |
General data - Features
Number of openers | 1 |
Number of shutters | 1 |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Actuating element | Roller lever |
Mechanical life, minimum | 5,000,000 Operations |
Actuating angle, from left of switch axis | 30 ° |
Actuating angle, from right of switch axis | 30 ° |
Contact opening | 2 x 1.2 mm |
Actuating speed, minimum | 1 mm/min |
Actuating speed, maximum | 1 m/s |
Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable section, minimum | 1.5 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section | 13 AWG |
Mechanical data - Dimensions
Length of the actuator | 21 mm |
Width of the actuator | 36 mm |
Height of the actuator | 73 mm |
Width of Castor | 8 mm |
Diameter of Castor | 36 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -30 °C |
Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 400 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 10 A |
Utilisation category AC-15 | 400 VAC |
Utilisation category AC-15 | 2.5 A |
Switching element | NO contact, NC contact |
Note (Switching element) | galvanically separated contact bridges |
Switching principle | Snap switch element |
Bounce duration, maximum | 2.5 ms |
Switching frequency | 3,000 /h |
Switchover time, maximum | 40 ms |