  • 1 x Pre-wired cable 8-pole
  • Actuation from side
  • serial diagnostic output
  • Max. 31 sensors can be wired in series.
  • Thermoplastic enclosure
  • Electronic contact-free, coded system
  • Misaligned actuation possible
  • 27 mm x 108.2 mm x 35 mm
  • High repeat accuracy of the switching points
  • Max. length of the sensor chain 200 m
  • 2 short-circuit proof PNP safety outputs
  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

Ordering data

Product type description

CSS 14-34-S-SD-M-L

Article number (order number)

101181061

EAN (European Article Number)

4030661314853

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

EAC

General data

Standards

IEC 60947-5-3

Active principle

inductive

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Glass-fibre, reinforced thermoplastic

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

295 g

Reaction time, maximum

30 ms

Duration of risk, maximum

60 ms

General data - Features

Serial diagnostics

Yes

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

3

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Number of Series-wiring of sensors

31

Safety appraisal

Standards

EN ISO 13849-1

IEC 60947-5-3

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

3.60 x 10⁻⁹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

lateral

Active area

lateral

Actuator switch distance

Actuator CST 180-1 / CST 180-2: 10 mm

Actuator CST 34-S-1: 14 mm

Actuator CST 34-S-2: 14 mm

Actuator CST 34-S-3: 14 mm

Actuator CST 34-S-1: 12 mm

Actuator CST 34-S-2: 12 mm

Actuator CST 34-S-3: 12 mm

Actuator CST 180-1 / CST 180-2: 8 mm

Actuator CST 34-S-1: 17 mm

Actuator CST 34-S-2: 17 mm

Actuator CST 34-S-3: 17 mm

Actuator CST 180-1 / CST 180-2: 13 mm

Hysteresis (Switch distance), maximum

1.5 mm

Repeat accuracy R R

0.5 mm

Note (Repeat accuracy R)

Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle)

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

10 mm

14 mm

Ensured switch distance ON Sao

12 mm

8 mm

Ensured switch distance OFF Sar

13 mm

17 mm

Mechanical data - Connection technique

Terminal Connector

Cable (Y-UL 2517), 8-pole

Length of cable

2 m

Cable section, maximum

8 x 0.35 mm²

Wire cross-section

22 AWG

Cable type

LiYY

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

35 mm

Width of sensor

27 mm

Height of sensor

108.2 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Resistance to vibrations to EN 60068-2-6

10 … 55 Hz, amplitude 1 mm

Restistance to shock

30 g / 11 ms

Protection rating

II

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Operating current

600 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

3 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Output current, (fail-safe output), maximum

0.25 A

Versions

p-type

Voltage drop Ud, maximum

0.5 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Electrical data - Diagnostic output

Operating current

150 mA

Versions

p-type

Voltage drop Ud, maximum

5 V

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 61000-6-2

Pin assignment

PIN 1

A1 Ue Brown

PIN 2

X1 Safety input 1 White

PIN 3

A2 GND Blue

PIN 4

Y1 Safety output 1 Black

PIN 5

SD serial diagnostic output: Grey

PIN 6

X2 Safety input 2 violet

PIN 7

Y2 Safety output 2 red

PIN 8

IN serial diagnostic input Pink

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

CST 34-S-2

CST 34-S-3

CST 180-1

CST 180-2

CST 34-S-1

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

Notes

Note (General)

Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary.