- Spring pulley connection
- Thermoplastic enclosure
- Max. length of the sensor chain 200 m
- Self-monitoring series-wiring
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
Ordering data
Note (Delivery capacity) | Phased-out product |
Product type description | AZ 200CC-T-1P2P |
Article number (order number) | 101182988 |
EAN (European Article Number) | 4030661318608 |
eCl@ss number, Version 9.0 | 27-27-26-02 |
eCl@ss number, Version 11.0 | 27-27-26-02 |
Available until | 31.12.2020 |
Approval - Standards
Certificates | TÜV cULus EAC |
General data
Standards | IEC 61508 IEC 60947-5-3 EN ISO 13849-1 |
Active principle | Non-contact |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 345 g |
Time to readiness, maximum | 4,000 ms |
Reaction time, maximum | 60 ms |
Duration of risk, maximum | 120 ms |
General data - Features
Actuator monitored | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety appraisal
Standards | IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 4.00 x 10⁻⁹ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Hysteresis (Switch distance), maximum | 1.5 mm |
Repeat accuracy R R | 0.5 mm |
Latching force | 30 N |
Actuating speed, maximum | 0.2 m/s |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 6.5 mm |
Ensured switch distance ON Sao | 4 mm |
Ensured switch distance OFF Sar | 30 mm |
Mechanical data - Connection technique
Terminal Connector | Spring pulley connection |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 1.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Wire cross-section, minimum | 23 AWG |
Wire cross-section, maximum | 15 AWG |
Mechanical data - Dimensions
Length of sensor | 50 mm |
Width of sensor | 40 mm |
Height of sensor | 220 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Relative humidity, minimum | 30 % |
Relative humidity, maximum | 95 % |
Note (Relative humidity) | non-condensing |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | II |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
No-load supply current I0 | 100 mA |
Rated operating voltage, minimum | 20.4 VDC |
Rated operating voltage, maximum | 26.4 VDC |
Operating current | 50 mA |
Switching frequency, approx. | 1 Hz |
Electrical data - Fail-safe digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 250 mA |
Versions | p-type |
Voltage drop Ud, maximum | 4 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Electrical data - Digital Output
Versions | p-type |
Electrical data - Diagnostic output
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage: LED green |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | AZ/AZM 200-B1 |