  • Explosion protection for ATEX Zones 2 and 22
  • Metal enclosure
  • Good resistance to oil and petroleum spirit
  • 40,5 mm x 76 mm x 38 mm
  • Actuator heads can be repositioned by 4 x 90°
  • Ex-certified screwed cable gland
  • Mounting details to EN 50041
  • 1 Cable entry M 20 x 1.5
  • Ex certified
  • only for positioning tasks

Ordering data

Product type description

EX-T4V10H 335-12Z-3G/D

Article number (order number)

101187625

EAN (European Article Number)

4030661335797

eCl@ss number, Version 9.0

27-27-26-01

eCl@ss number, Version 11.0

27-27-26-01

ETIM number, version 6.0

EC000030

ETIM number, version 7.0

EC000030

Approval - Standards

Certificates

cULus

Explosion protection

Explosion protection: regulations

BG-GS-ET-15

EN 60079-0

EN 60079-15

EN 60079-31

EN 60947-5-1

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

D II 3G Ex nC IIC T5 Gc X

D II 3D Ex tc IIIC T90°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Housing construction form

Norm construction design

Enclosure material

Aluminium

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Lever material

Metal film

Material of the rod

Plastic

Gross weight

305 g

General data - Features

Number of auxiliary contacts

1

Number of safety contacts

2

Safety appraisal

Standards

EN ISO 13849-1

Mission Time

20 Year(s)

Safety appraisal - Safety outputs

B10d Normally-closed contact (NC)

20,000,000 Operations

Mechanical data

Actuating element

Rod lever

Mechanical life, minimum

30,000,000 Operations

Impact energy, maximum

4 J

Actuating speed, maximum

2.5 m/s

Note (Actuating speed)

Actuating speed with actuating angle 30° to switch axis

Note (Switchover time)

Switchover time in accordance with actuating speed

Actuating torque, minimum

0.3 Nm

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable cross-section of the cable glands, minimum

7 mm

Cable cross-section of the cable glands, maximum

12 mm

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Wire cross-section

13 AWG

Mechanical data - Dimensions

Length x Width x Height

Height of sensor: 111.5 mm (without rod)

Length of sensor

38 mm

Width of sensor

40.5 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-20 °C

Ambient temperature, maximum

+60 °C

Ambient conditions - Insulation value

Rated insulation voltage Ui

250 V

Rated impulse withstand voltage Uimp

4 kV

Electrical data

Thermal test current

10 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

NO contact, NC contact

Switching principle

Slow action

Bounce duration, maximum

2 ms

Switching frequency

5,000 /h

Наш менеджер свяжется с вами в ближайшее время