- Ex-Zone 22
- Metal enclosure
- 130 mm x 100 mm x 46,5 mm
- Clamping force 3500N
- 2 switches in one enclosure
- Adjustable ball latch to 400 N
- Interlock with protection against incorrect locking.
- Problem-free opening of stressed doors by means of bell-crank system
- 2 cable entries M 20 x 1.5
Ordering data
Product type description | EX-AZM 415-02/02ZPKA 24VAC/DC-3D |
Article number (order number) | 101194202 |
EAN (European Article Number) | 4030661358338 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
eCl@ss number, Version 11.0 | 27-27-26-03 |
Explosion protection
Explosion protection: regulations | BG-GS-ET-19 EN 60079-0 |
Explosion protection zones | 22 |
Explosion protection category | 3D |
Explosion protection designation | D II 3D Ex tc IIIC T90°C Dc X |
Manufacturer declaration | ATEX Zone 22 |
General data
Standards | IEC 60947-5-1 |
Active principle | electromechanical |
Enclosure material | Aluminium |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Gross weight | 976 g |
General data - Features
Power to lock | Yes |
Number of actuating directions | 1 |
Number of safety contacts | 4 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Impact energy, maximum | 4 J |
Clamping force | 3,500 N |
Latching force, minimum | 80 N |
Latching force, maximum | 400 N |
positive break travel | 5 mm |
Positive break force, minimum | 15 N |
Actuating speed, maximum | 1 m/s |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable cross-section of the cable glands, minimum | 7 mm |
Cable cross-section of the cable glands, maximum | 12 mm |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 46.5 mm |
Width of sensor | 130 mm |
Height of sensor | 100 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature, minimum | -10 °C |
Ambient temperature, maximum | +50 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 6 A |
Rated control voltage | 24 VAC |
Rated control voltage | 24 VDC |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Electrical power consumption, maximum | 10 W |
Switching element | NO contact, NC contact |
Switching principle | Creep circuit element |
Scope of delivery
Included in delivery | Actuators must be ordered separately. Including Ex-certified screwed cable gland and screw plug |