- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- Ø M12
- Particularly large switching distance
- Insensitive to transverse misalignment
- Suitable for food processing industry only in combination with BP 15 SS
- no mechanical wear
Ordering data
Product type description | EX-BNS 120-02Z-3G/D 5,0M |
Article number (order number) | 101213462 |
EAN (European Article Number) | 4030661396231 |
eCl@ss number, Version 9.0 | 27-27-24-02 |
Explosion protection
Explosion protection: regulations | EN 60079-0 EN 60079-31 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nC IIC T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Standards | IEC 60947-5-3 |
Housing construction form | Cylinder, thread |
Installation conditions (mechanical) | quasi-flush |
Enclosure material | Glass-fibre, reinforced thermoplastic |
Gross weight | 200 g |
General data - Features
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Number of openers | 2 |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 25,000,000 Operations |
Mechanical data
Active area | front side |
Actuating element | Magnet |
Actuator switch distance | Actuating magnet BP 8, Sao: 10 mm Actuating magnet BP 15 SS, Sao: 20 mm Actuating magnet BP 10, Sao: 20 mm Actuating magnet BP 6, Sao: 10 mm Actuating magnet BP 8, Sar: 22 mm Actuating magnet BP 15 SS, Sar: 32 mm Actuating magnet BP 10, Sar: 32 mm |
Impact energy, maximum | 2 J |
Direction of motion | Head-on to the active surface |
Mechanical data - Switching distances according IEC 60947-5-3
Ensured switch distance ON Sao | 10 mm 20 mm |
Ensured switch distance OFF Sar | 22 mm 32 mm |
Mechanical data - Connection technique
Terminal Connector | Cable |
Length of cable | 5 m |
Wire cross-section | 0.25 mm2 |
Wire cross-section | 23 AWG |
Material of the Cable mantle | PVC |
Mechanical data - Dimensions
ISO thread of the sensor | M12 |
Length of sensor | 38.5 mm |
Ambient conditions
Degree of protection | IP67 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +70 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +70 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Electrical data
Voltage type | AC (alternating current) DC (direct current) |
Switching voltage, maximum | 100 VAC |
Switching voltage, maximum | 100 VDC |
Switching current, maximum | 0.25 A |
Switching capacity, maximum | 3 W |
Switching frequency, maximum | 5 Hz |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | BP 10 BP 8 BP 6 BP 15 SS |
Recommended safety switchgear | SRB-E-301ST SRB-E-201LC |
Notes
Note (General) | Contact symbols shown for the closed condition of the guard device. The safety sensor must be mounted in such a way that actuation with another magnet is impossible (concealed mounting according to ISO 14119) |