- IDC method of termination
- Manual release
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- 1 Cable entry M 20 x 1.5
- Interlock with protection against incorrect locking.
- High holding force
- 90 mm x 84 mm x 30 mm
Ordering data
Product type description | EX-AZM 170-02ZKA 24VAC/DC-3G/D |
Article number (order number) | 101216375 |
EAN (European Article Number) | 4030661406886 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
Explosion protection
Explosion protection: regulations | EN 60079-0 EN 60079-15 EN 60079-31 EN 60947-5-1 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nC IIB T5 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Material of the contacts, electrical | Silver |
Gross weight | 290 g |
General data - Features
Power to lock | Yes |
Manual release | Yes |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Impact energy, maximum | 1 J |
Clamping force | 1,000 N |
Latching force | 5 N |
positive break travel | 11 mm |
Positive break force, minimum | 17 N |
Actuating speed, maximum | 1 m/s |
Mechanical data - Connection technique
Terminal Connector | IDC method of termination |
Cable cross-section of the cable glands, minimum | 6.5 mm |
Cable cross-section of the cable glands, maximum | 12 mm |
Cable section, minimum | 2 x 1.0 mm², flexible |
Cable section, maximum | 1 x 1 mm², flexible |
Mechanical data - Dimensions
Length of sensor | 30 mm |
Width of sensor | 90 mm |
Height of sensor | 84 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -15 °C |
Ambient temperature, maximum | +45 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
Thermal test current | 2 A |
Rated control voltage | 24 VAC |
Rated control voltage | 24 VDC |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 2 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 2 A |
Electrical power consumption, maximum | 10 W |
Switching element | Opener (NC) |
Switching principle | Creep circuit element |
Scope of delivery
Included in delivery | Actuators must be ordered separately. Including Ex-certified screwed cable gland and screw plug |
Notes
Note (General) | This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules |
Note (Manual release) | bottom For manual release using M5 triangular key, available as accessory |