  • Explosion protection for ATEX Zones 2 and 22
  • Metal enclosure
  • Good resistance to oil and petroleum spirit
  • 40,5 mm x 76 mm x 38 mm
  • Actuator heads can be repositioned by 4 x 90°
  • Ex-certified screwed cable gland
  • Mounting details to EN 50041
  • 1 Cable entry M 20 x 1.5
  • Ex certified

Ordering data

Product type description

EX-T4VH 335-20ZH-3G/D

Article number (order number)

101217362

EAN (European Article Number)

4030661411750

eCl@ss number, Version 9.0

27-27-26-01

Approval - Standards

Certificates

cULus

Explosion protection

Explosion protection: regulations

BG-GS-ET-15

EN 60079-0

EN 60079-15

EN 60079-31

EN 60947-5-1

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

D II 3G Ex nC IIC T5 Gc X

D II 3D Ex tc IIIC T90°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Housing construction form

Norm construction design

Actuator type to DIN EN 50041

A

Enclosure material

Aluminium

Enclosure coating material

painted

Material of the contacts, electrical

Silver

Lever material

Metal film

Roller material

Plastic

Gross weight

360 g

General data - Features

Number of auxiliary contacts

2

Number of safety contacts

0

Safety appraisal

Standards

EN ISO 13849-1

Mission Time

20 Year(s)

Mechanical data

Actuating element

Roller lever

Mechanical life, minimum

30,000,000 Operations

Impact energy, maximum

4 J

Actuating speed, maximum

2.5 m/s

Note (Actuating speed)

Actuating speed with actuating angle 30° to switch axis

Note (Switchover time)

Switchover time in accordance with actuating speed

Actuating torque, minimum

0.3 Nm

Mechanical data - Connection technique

Terminal Connector

Screw connection

Cable cross-section of the cable glands, minimum

7 mm

Cable cross-section of the cable glands, maximum

12 mm

Cable section, minimum

0.75 mm²

Cable section, maximum

2.5 mm²

Note (Cable section)

All indications about the cable section are including the conductor ferrules.

Wire cross-section

13 AWG

Mechanical data - Dimensions

Length of sensor

60.6 mm

Width of sensor

40.5 mm

Height of sensor

134 mm

Ambient conditions

Degree of protection

IP67

Ambient temperature, minimum

-20 °C

Ambient temperature, maximum

+60 °C

Ambient conditions - Insulation value

Rated insulation voltage Ui

500 V

Rated impulse withstand voltage Uimp

6 kV

Electrical data

Thermal test current

10 A

Utilisation category AC-15

230 VAC

Utilisation category AC-15

4 A

Utilisation category DC-13

24 VDC

Utilisation category DC-13

1 A

Switching element

Normally open contact (NO)

Switching principle

Slow action with staggered contacts

Bounce duration, maximum

2 ms

Switching frequency

5,000 /h