- Pre-wired cable 7-pole
- Comfortable diagnostics through sensor LED and electronic signalling output
- Ex certified
- Thermoplastic enclosure
- Non-contact, coded electronic safety sensor for use in areas of zone
with gas and dust-explosion hazard - Category 3GD, ATEX Zone 2 and 22
- High repeat accuracy of the switching points
- Misaligned actuation possible
- Early warning when operating near the limit of the sensor's hysteris range
- Self-monitoring series-wiring of 16 sensors
- Suitable for applications up to PL e / SIL 3
Ordering data
Note (Delivery capacity) | Not available! |
Product type description | EX-CSS 8-16-2P+D-M-L-3G/D |
Article number (order number) | 103003015 |
EAN (European Article Number) | 4030661427195 |
Explosion protection
Explosion protection: regulations | EN 60079-0 EN 60079-15 EN 60079-31 |
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3G Ex nA IIB T6 Gc X D II 3D Ex tc IIIC T80°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Active principle | inductive |
Housing construction form | Block |
Installation conditions (mechanical) | not flush |
Sensor topology | Sensor for series wiring Individual sensor or end sensor in a series |
Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
Active area | Glass-fibre, reinforced thermoplastic |
Gross weight | 278 g |
Reaction time, maximum | 30 ms |
Duration of risk, maximum | 30 ms |
General data - Features
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Safety functions | Yes |
Cascadable | Yes |
Integral System Diagnostics, status | Yes |
Number of semi-conductor outputs with signaling function | 1 |
Number of fail-safe digital outputs | 2 |
Number of Series-wiring of sensors | 16 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 60947-5-3 IEC 61508 | |
Performance level, up to | e | |
Control category to EN13849 | 4 | |
PFH-value | 6.10 x 10⁻⁹ /h | |
| 3 | |
Mission Time | 20 Year(s) |
Mechanical data
Hysteresis (Switch distance), maximum | 1 mm |
Repeat accuracy R R | 0.5 mm |
Mechanical data - Switching distances according IEC 60947-5-3
Switch distance | 8 mm |
Ensured switch distance ON Sao | 6 mm |
Ensured switch distance OFF Sar | 11 mm |
Mechanical data - Connection technique
Terminal Connector | Cable |
Length of cable | 2 m |
Terminal connector, Input/Output | 7-pole |
Wire cross-section | 0.25 mm2 |
Wire cross-section | 23 AWG |
Mechanical data - Dimensions
Length of sensor | 39.5 mm |
Width of sensor | 55 mm |
Height of sensor | 93 mm |
Ambient conditions
Degree of protection | IP65 to EN 60529 IP67 to EN 60529 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -25 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | II |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
Voltage type | DC (direct current) |
No-load supply current I0 | 50 mA |
Rated operating voltage, minimum | 20.4 V |
Rated operating voltage, maximum | 26.4 V |
Operating current | 500 mA |
Switching frequency, approx. | 3 Hz |
Electrical data - Fail-safe digital outputs
Versions | p-type |
Voltage drop Ud, maximum | 0.5 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.5 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.5 A |
Electrical data - Digital Output
Versions | p-type |
Electrical data - Diagnostic output
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.05 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Multi-coloured LED: Green, Red, Yellow |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Accessory
Recommendation (actuator) | CST 16-1 |
Notes
Note (General) | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circuit recognition by the evaluation is not necessary. |