- 3 cable entries M 20 x 1.5
- Ex-Zone 22
- Metal enclosure
- Release push button
- Position indicator
- Robust design
- Large wiring compartment
- Twisting of towing eye not possible
- External watertight collar
- wire pull and breakage detection
- one-side operation / wire up to 75 m long
Ordering data
Product type description | EX-ZQ 900-02-3D |
Article number (order number) | 103012458 |
EAN (European Article Number) | 4030661483450 |
eCl@ss number, Version 9.0 | 27-27-26-01 |
Explosion protection
Explosion protection: regulations | EN 60079-31 IEC 60079-0 |
Explosion protection zones | 22 |
Explosion protection category | 3D |
Explosion protection designation | D II 3D Ex tc IIIC T100°C Dc |
Manufacturer declaration | ATEX Zone 22 |
General data
Standards | IEC/EN 60947-5-1 EN ISO 13850 IEC/EN 60947-5-5 |
Enclosure material | Zinc die-cast |
Enclosure coating material | painted |
Material of the contacts, electrical | Silver |
Material of the cover | Steel |
Length of the wire, maximum | 75 m |
Gross weight | 1,650 g |
General data - Features
Number of auxiliary contacts | 0 |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 |
Mission Time | 20 Year(s) |
Safety appraisal - Safety outputs
B10d Normally-closed contact (NC) | 100,000 Operations |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Actuating force, maximum | 200 N |
Actuating travel | 400 mm |
Mechanical data - Connection technique
Terminal Connector | Screw connection |
Cable cross-section of the cable glands, minimum | 7 mm |
Cable cross-section of the cable glands, maximum | 12 mm |
Cable section, minimum | 0.75 mm² |
Cable section, maximum | 2.5 mm² |
Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
Length of sensor | 57 mm |
Width of sensor | 71.5 mm |
Height of the Sensor, minimum | 221 mm |
Height of the Sensor, maximum | 237 mm |
Ambient conditions
Degree of protection | IP67 to EN 60529 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +55 °C |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 500 V |
Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
Thermal test current | 4 A |
Utilisation category AC-15 | 230 VAC |
Utilisation category AC-15 | 4 A |
Utilisation category DC-13 | 24 VDC |
Utilisation category DC-13 | 1 A |
Switching element | NO contact, NC contact |
Switching principle | Snap switch element |
Scope of delivery
Included in delivery | Including Ex-certified screwed cable gland and screw plug |
Notes
Note (General) | For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. |