- Explosion protection for ATEX Zones 2 and 22
- RFID-technology for needs-based protection against tampering
- Thermoplastic enclosure
- Suitable for mounting to profile systems
- 3 different directions of actuation
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
- Manual release
Ordering data
Product type description | EX-AZM300B-ST-1P2P-A-CL |
Article number (order number) | 103012541 |
EAN (European Article Number) | 4030661483924 |
eCl@ss number, Version 9.0 | 27-27-26-03 |
Explosion protection
Explosion protection zones | 22 2 |
Explosion protection category | 3D 3G |
Explosion protection designation | D II 3GD EX nA IIB T5 Gc EX tc IIIB T95°C Dc X |
Manufacturer declaration | ATEX Zone 2 and 22 |
General data
Standards | IEC 60947-5-1 EN ISO 13849-1 IEC 61508 IEC 60947-5-3 | |
Coding level according to ISO 14119 | Low | |
Active principle | RFID | |
Enclosure material | Glass-fibre, reinforced thermoplastic | |
Material of the fixing screws | Stainless steel (V4A) | |
Gross weight | 1,062 g | |
Time to readiness, maximum | 5,000 ms | |
Reaction time, maximum | 120 ms | |
Duration of risk, maximum | 200 ms | |
| 100 ms | |
| 0.5 ms |
General data - Features
Power to lock | Yes |
Actuator monitored | Yes |
Latching | Yes |
Manual release | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Series-wiring | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of safety contacts | 2 |
Safety appraisal
Standards | EN ISO 13849-1 IEC 62061 IEC 61508 |
Safety appraisal - Interlocking
Performance level, up to | e |
Control category | 4 |
PFH-value | 5.20 x 10⁻¹⁰ /h |
PFD value | 4.50 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Mechanical data
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical lifetime) | When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s) |
Impact energy, maximum | 7 J |
Clamping force in accordance with ISO14119 Fzh | 1,150 N |
Clamping force, maximum Fmax | 1,500 N |
Latching force, adjustable, position 1 | 25 N |
Latching force, adjustable, position 2 | 50 N |
Type of the fixing screws | 2x M6 |
Mechanical data - Switching distances according IEC 60947-5-3
Ensured switch distance ON Sao | 1 mm |
Ensured switch distance OFF Sar | 20 mm |
Mechanical data - Connection technique
Terminal Connector | Connector M12, 8-pole, A-coded |
Mechanical data - Dimensions
Width of sensor | 85 mm |
Ambient conditions
Degree of protection | IP66 to EN 60529 IP67 to EN 60529 IP69 to EN 60529 |
Ambient temperature, minimum | +0 °C |
Ambient temperature, maximum | +50 °C |
Storage and transport temperature, minimum | -10 °C |
Storage and transport temperature, maximum | +90 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value
Rated insulation voltage Ui | 32 VDC |
Rated impulse withstand voltage Uimp | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data
No-load supply current I0 | 100 mA |
Operating current | 50 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 0.5 Hz |
Electrical data - Solenoid control
Switching thresholds | -3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V | 10 mA |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital inputs
Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Current consumption at 24V | 5 mA |
Classification ZVEI CB24I, Sink | C1 |
Classification ZVEI CB24I, Source | C1 C2 C3 |
Electrical data - Fail-safe digital outputs
Rated operating current (safety outputs) | 250 mA |
Versions | short-circuit proof, p-type |
Voltage drop Ud, maximum | 4 V |
Current leakage Ir | 0.5 mA |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.25 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.25 A |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 C2 |
Electrical data - Diagnostic output
Versions | short-circuit proof, p-type |
Voltage drop Ud, maximum | 4 V |
Voltage, Utilisation category DC12 | 24 VDC |
Current, Utilisation category DC12 | 0.05 A |
Voltage, Utilisation category DC13 | 24 VDC |
Current, Utilisation category DC13 | 0.05 A |
Status indication
Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
PIN 1 | A1 Supply voltage UB |
PIN 2 | X1 Safety input 1 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | X2 Safety input 2 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | IN Solenoid control |
Scope of delivery
Included in delivery | Actuators must be ordered separately. |
Notes
Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |