Бренды по алфавиту:
А Б В Г Д Е Ё Ж З И Й К Л М Н О П Р С Т У Ф Х Ц Ч Ш Щ Ъ Ы Ь Э Ю Я
Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
  • Explosion protection for ATEX Zones 2 and 22
  • RFID-technology for needs-based protection against tampering
  • Thermoplastic enclosure
  • Suitable for mounting to profile systems
  • 3 different directions of actuation
  • 3 LEDs to show operating conditions
  • Suitable for hinged and sliding guards
  • Series-wiring
  • Manual release

Ordering data

Product type description

EX-AZM300B-ST-1P2P-A-CL

Article number (order number)

103012541

EAN (European Article Number)

4030661483924

eCl@ss number, Version 9.0

27-27-26-03

Explosion protection

Explosion protection zones

22

2

Explosion protection category

3D

3G

Explosion protection designation

D II 3GD

EX nA IIB T5 Gc

EX tc IIIB T95°C Dc X

Manufacturer declaration

ATEX Zone 2 and 22

General data

Standards

IEC 60947-5-1

EN ISO 13849-1

IEC 61508

IEC 60947-5-3

Coding level according to ISO 14119

Low

Active principle

RFID

Enclosure material

Glass-fibre, reinforced thermoplastic

Material of the fixing screws

Stainless steel (V4A)

Gross weight

1,062 g

Time to readiness, maximum

5,000 ms

Reaction time, maximum

120 ms

Duration of risk, maximum

200 ms

Response time safety outputs in case of switch-off by actuator, maximum

100 ms

Response time safety outputs in case of switch-off by safety inputs, maximum

0.5 ms

General data - Features

Power to lock

Yes

Actuator monitored

Yes

Latching

Yes

Manual release

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Integral System Diagnostics, status

Yes

Number of safety contacts

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 62061

IEC 61508

Safety appraisal - Interlocking

Performance level, up to

e

Control category

4

PFH-value

5.20 x 10⁻¹⁰ /h

PFD value

4.50 x 10⁻⁵

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Mechanical life, minimum

1,000,000 Operations

Note (Mechanical lifetime)

When using as door stop: ≥ 50.000 operations (door mass ≤ 5 kg and actuating speed ≤ 0.5 m/s)

Impact energy, maximum

7 J

Clamping force in accordance with ISO14119 Fzh

1,150 N

Clamping force, maximum Fmax

1,500 N

Latching force, adjustable, position 1

25 N

Latching force, adjustable, position 2

50 N

Type of the fixing screws

2x M6

Mechanical data - Switching distances according IEC 60947-5-3

Ensured switch distance ON Sao

1 mm

Ensured switch distance OFF Sar

20 mm

Mechanical data - Connection technique

Terminal Connector

Connector M12, 8-pole, A-coded

Mechanical data - Dimensions

Width of sensor

85 mm

Ambient conditions

Degree of protection

IP66 to EN 60529

IP67 to EN 60529

IP69 to EN 60529

Ambient temperature, minimum

+0 °C

Ambient temperature, maximum

+50 °C

Storage and transport temperature, minimum

-10 °C

Storage and transport temperature, maximum

+90 °C

Resistance to vibrations to EN 60068-2-6

10 … 150 Hz, amplitude 0.35 mm

Restistance to shock

30 g / 11 ms

Protection rating

III

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

No-load supply current I0

100 mA

Operating current

50 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

0.5 Hz

Electrical data - Solenoid control

Switching thresholds

-3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

10 mA

Classification ZVEI CB24I, Sink

C0

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital inputs

Switching thresholds

−3 V … 5 V (Low)

15 V … 30 V (High)

Current consumption at 24V

5 mA

Classification ZVEI CB24I, Sink

C1

Classification ZVEI CB24I, Source

C1

C2

C3

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

250 mA

Versions

short-circuit proof, p-type

Voltage drop Ud, maximum

4 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.25 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.25 A

Classification ZVEI CB24I, Source

C2

Classification ZVEI CB24I, Sink

C1

C2

Electrical data - Diagnostic output

Versions

short-circuit proof, p-type

Voltage drop Ud, maximum

4 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Status indication

Note (LED switching conditions display)

Operating condition: LED green

Error / functional defect: LED red

Supply voltage UB: LED green

Pin assignment

PIN 1

A1 Supply voltage UB

PIN 2

X1 Safety input 1

PIN 3

A2 GND

PIN 4

Y1 Safety output 1

PIN 5

OUT Diagnostic output

PIN 6

X2 Safety input 2

PIN 7

Y2 Safety output 2

PIN 8

IN Solenoid control

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Notes

Note (General)

For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used.

For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used.

As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.