Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Strain Sensors
- Highest protection rating IP 69K
- Tested long term seal according to proTect+
- Corrosion protection C5-M
- Measuring range ±100 ... 1000 µm/m
- Output signal ± 10 VDC, CANopen
- Integrated amplifier electronics
general data
- Nominal strain
-
- 100 ... 1000 μm/m
- Non-linearity
-
- < 0.5 %
- Repeatability
-
- < 0.1 %
electrical data
- Output signal
-
- CANopen DS404
- ± 10 VDC
- Supply voltage
-
- 10 ... 33 VDC CANopen DS404
- 18 ... 33 VDC Voltage output
- Signal polarity positive
-
- Tension
- Current consumption
-
- < 60 mA
- Measuring resolution
-
- 0.1 με
- Sampling rate
-
- 1000 samples/s
- Data format
-
- fixed-point
mechanical data
- Weight
-
- 330 g
- Material sensor body
-
- 1.7225, chemically nickel plated
- Material housing
-
- Stainless steel, 1.4301
- Material sealing
-
- NBR
- Electrical connection
-
- M12, 5 pin, male
environmental conditions
- Operating temperature range
-
- -40 ... +85 °C
- Storage temperature range
-
- -40 ... +85 °C
- Protection class EN 60529, ISO20653
-
- IP 68, 168h@ 1 m H2O
- IP 69K
- proTect+
- Vibration IEC 60068-2-6
-
- 10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
- Random IEC 60068-2-64
-
- 20 ... 1000 Hz: 0.1 g²/Hz
- Shock IEC 60068-2-27
-
- 50 g / 11 ms, 100 g / 6 ms
Compliance and approvals
- EMC
-
- EN 61000-6-2
- EN 61000-6-3
- EN 61326-2-3
- UL listed
-
- E217824
Baumer_DST55R_CANopen_eds.zip
Baumer_DST55R_DE-EN-FR_CoC_81306830.pdf
Dehntrafos_DST55R.igs
en_BA_CANopen_Konfiguration_Dehnungssensoren.pdf
en_DAB_DST55R.pdf
Baumer_DST55R_DE-EN-FR_CoC_81306830.pdf
Dehntrafos_DST55R.igs
en_BA_CANopen_Konfiguration_Dehnungssensoren.pdf
en_DAB_DST55R.pdf
Наш менеджер свяжется с вами в ближайшее время