Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
Flow measurementHygienic flow sensor
- SIP- capable without restrictions up to 150 °C / 24h
- Broad portfolio of process connections
- Flow and temperature measurement in a single sensor
- Compact and robust
- Available with IO-Link interface
Performance characteristics
- Measuring range, flow
- 10 … 400 cm/s
- Measuring range, temperature
- -25 … 150 °C
- Max. measuring error
- ± 2 % FSR , flow measurement
- ± 8 cm/s , flow measurement
- ± 1 °C , temperature measurement @ flow > 0 cm/s
- Response time, T90
- < 5 s
- Down time at temperature step
- < 10 s
Process conditions
- Process temperature
- -25 … 125 °C , flow measurement
- -25 … 150 °C , temperature measurement @ flow > 0 cm/s
Process connection
- Wetted parts material
- AISI 316L (1.4404)
- Surface roughness wetted parts
- Ra ≤ 0.8 µm
Ambient conditions
- Degree of protection (EN 60529)
- IP 67
- IP 68 , 30 min. @ 1 mH2O
- IP 69K , with appropriate cable
- Shock (EN 60068-2-27)
- 30 g / 11 ms, 6 impulses per axis and direction
- Vibration (sinusoidal) (EN 60068-2-6)
- 5 g (10 ... 2000 Hz)
Output signal
- Current output
- 4 … 20 mA
- Voltage output
- 0… 10 V
- Output type
- Digital (push-pull)
- NPN
- PNP
- Switching logic
- Active high
- Active low
- Normally closed (NC)
- Normally open (NO)
- Interface
- IO-Link 1.1
Compliance and approvals
- Hygiene
- (EC) No 1935/2004
- (EC) No 2023/2006
- FDA compliant
- EAC (Eurasian Conformity)
- EAC (TR CU 020/2011)
Baumer_FlexFlow_PF20H_EN_1706_BR_11186786.pdf
Baumer_Flowcalculator_EN.xlsx
Baumer_IO-Link_Parameter_u_Prozessdaten_PF20x-11-xxx_EN.pdf
Baumer_PF20H_EN_20191106_DS.pdf
Baumer_PF20_DE-EN-FR_FRDoH_81264845.pdf
PF20H-3D.zip
Baumer_Flowcalculator_EN.xlsx
Baumer_IO-Link_Parameter_u_Prozessdaten_PF20x-11-xxx_EN.pdf
Baumer_PF20H_EN_20191106_DS.pdf
Baumer_PF20_DE-EN-FR_FRDoH_81264845.pdf
PF20H-3D.zip
Наш менеджер свяжется с вами в ближайшее время