                Absolute encodersEx approval Ex II 2D/2G (ATEX) 
                - Encoder multiturn / CANopen® / ATEX
- Optical sensing method
- Resolution: singleturn 18 bit, multiturn 14 bit
- Clamping flange with solid shaft ø10 mm
- Explosion protection per Ex II 2D/2G (ATEX)
- Device class 2 / zone 1 (gas), zone 21 (dust)
- Galvanic isolation
- Maximum resistant against magnetic fields
Technical data - electrical ratings
- Voltage supply
- 10...30 VDC
 
- Reverse polarity protection
- Yes
 
- Consumption w/o load
- ≤50 mA (24 VDC)
 
- Initializing time typ.
- 250 ms after power on
 
- Interface
- CANopen®
 
- Function
- Multiturn
 
- Transmission rate
- 10 … 1000 kBaud
 
- Operating mode
- Event-triggered / Time-triggered Remotely-requested Sync (cyclic) / Sync (acyclic)
 
- Identifier
- 11 bit
 
- Steps per revolution
- ≤262144 / 18 bit
 
- Number of revolutions
- ≤16384 / 14 bit
 
- Absolute accuracy
- ±0,025 °
 
- Sensing method
- Optical
 
- Code
- Binary
 
- Code sequence
- CW/CCW programmable
 
- Output stages
- CAN bus standard ISO / DIS 11898
 
- Interference immunity
- DIN EN 61000-6-2
 
- Emitted interference
- DIN EN 61000-6-4
 
- Programmable parameters
- Operating modes
- Total resolution
- Scaling
- Rotation speed monitoring
 
- Diagnostic function
- Position or parameter error
- Multiturn sensing
 
Technical data - mechanical design
- Size (flange)
- ø70 mm
 
- Shaft type
- ø10 mm solid shaft (clamping flange)
 
- Flange
- Clamping flange
 
- Protection DIN EN 60529
- IP 67
 
- Operating speed
- ≤6000 rpm (mechanical)
- ≤6000 rpm (electric)
 
- Starting acceleration
- ≤1000 U/s²
 
- Starting torque
- ≤0,4 Nm (+25 °C)
 
- Admitted shaft load
- ≤60 N axial
- ≤50 N radial
 
- Material
- Housing: stainless steel
- Flange: stainless steel
 
- Operating temperature
- -20...+70 °C
 
- Relative humidity
- 95 % non-condensing
 
- Resistance
- DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz
- DIN EN 60068-2-27 Shock 200 g, 6 ms
 
- Explosion protection
- Ex II 2G Ex d IIC T6
- Ex II 2D
 
- Weight approx.
- 1300 g
 
- Connection
- Cable 2 m (other length upon request)
 
                        