- 4 contacts per pedal
- 3-phase actuation with pressure point
- Also available as safety foot switch
- Low operating height of pedal
- Cable entry M 20 x 1.5
- High level of stability
- Metal enclosure
- single-pedal types
Ordering data
| Note (Delivery capacity) | Not available! | 
| Product type description | T2F 232-40HD/40HD | 
| Article number (order number) | 101182022 | 
| EAN (European Article Number) | 4030661326658 | 
General data
| Standards | BG-GS-ET-15 DIN VDE 0660-200 EN 60947-5-1 | 
| Enclosure material | Aluminium | 
| Enclosure coating material | powder-coated | 
| Material of the cover | Aluminium | 
| Material of the pedal | Glass-fibre, reinforced thermoplastic | 
| Material of the protective shield | Aluminium | 
| Colour of the housing | RAL 9006 (White aluminum) | 
| Gross weight | 2,100 g | 
General data - Features
| Staggered contacts | Yes | 
| Probing possible | Yes | 
| Number of pedals, NO | 4 | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, maximum | 1 x 2.5 mm² | 
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. | 
Mechanical data - Dimensions
| Width | 170 mm | 
| Height | 189 mm | 
| Depth | 274 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +70 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 500 V | 
| Rated impulse withstand voltage Uimp | 6 kV | 
Electrical data
| Thermal test current | 10 A | 
| Utilisation category AC-15 | 230 VAC | 
| Utilisation category AC-15 | 4 A | 
| Utilisation category DC-13 | 24 VDC | 
| Utilisation category DC-13 | 1 A | 
| Switching element | Normally open contact (NO) | 
| Switching principle | Slow action | 
Notes
| Note (General) | The pressure point can only be ordered for 2 NO or 4 NO contacts per pedal and is only available with slow action (T). For each contact specification, the pressure point must be specified individually., e.g. TFH 232-11hd or T2FH 232-11hd/11hd | 
 
                





 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  