Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на zakaz@lanfor.ru
- 1 Cable entry PG9 x 1.5
- Thermoplastic enclosure
- AC 2-wire
- Double-insulated
- Wiring compartment
- Design M 18 x 1
Ordering data
| Product type description | IFL 10-180-10/01YG |
| Article number (order number) | 101091876 |
| EAN (European Article Number) | 4030661018317 |
| eCl@ss number, Version 9.0 | 27-27-01-01 |
| eCl@ss number, Version 11.0 | 27-27-01-01 |
| ETIM number, version 6.0 | EC002714 |
| ETIM number, version 7.0 | EC002714 |
Approval - Standards
| Certificates | CCC |
General data
| Standards | DIN VDE 0660-208 IEC/EN 60947-5-2 |
| Housing construction form | Cylinder, thread |
| Installation conditions (mechanical) | not flush |
| Enclosure material | Plastic |
| Active area | Plastic |
| Material of the nuts | Plastic |
| Material of the washer | Perbunan® |
| Gross weight | 50 g |
General data - Features
| Integral System Diagnostics, status | Yes |
| Number of cable wires | 2 |
Mechanical data
| Tightening torque of nuts, maximum | 3 Nm |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 10 mm |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable section, maximum | 1 x 1.5 mm² |
Mechanical data - Dimensions
| ISO thread of the sensor | M18 |
| width across flats | 24 BK |
| Length of sensor | 126 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +70 °C |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated impulse withstand voltage Uimp | 4 kV |
Electrical data
| Voltage type | AC (alternating current) |
| Rated supply frequency, minimum | 45 Hz |
| Rated supply frequency, maximum | 65 Hz |
| Operating voltage, minimum | 15 V |
| Operating voltage, maximum | 250 V |
| Operating current, minimum | 10 mA |
| Operating current | 500 mA |
| Switching element | NO contact or NC contact |
| Protection circuit integrated | inductive interference protection |
| Switching frequency, approx. | 10 Hz |
Electrical data - Digital Output
| Voltage drop Ud, maximum | 4.5 V |
| Current at Voltage drop Ud | 0.2 A |
| Versions | Two-wire |
| Current leakage Ir | 1 mA |
Status indication
| Note (Integral System Diagnostics, status ) | yellow LED |
Notes
| Note (General) | Instead of nuts, a mounting clamp can be provided. Programmable by repositioning the plug-in jumper at the terminal screws |
Наш менеджер свяжется с вами в ближайшее время
