- Safety switch with separate actuator
- Thermoplastic enclosure
- Integrated AS-Interface
- 40 mm x 220 mm x 50 mm
- 3 LEDs to show operating conditions
- Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
- Intelligent diagnosis
- With door detection sensor T
- Protection class IP67
Ordering data
| Note (Delivery capacity) | Phased-out product |
| Product type description | AZ 200ST-T-AS |
| Article number (order number) | 101190950 |
| EAN (European Article Number) | 4030661356440 |
| eCl@ss number, Version 9.0 | 27-27-26-02 |
| eCl@ss number, Version 11.0 | 27-27-26-02 |
| Available until | 31.12.2020 |
Approval - Standards
| Certificates | TÜV cULus ASi-SaW EAC |
General data
| Standards | IEC 61508 IEC 60947-5-3 EN 60947-5-1 EN 50295 EN ISO 13849-1 |
| Active principle | Non-contact |
| Enclosure material | Glass-fibre, reinforced thermoplastic |
| Gross weight | 335 g |
| Time to readiness, maximum | 4,000 ms |
| Reaction time, maximum | 60 ms |
| Duration of risk, maximum | 120 ms |
General data - Features
| Actuator monitored | Yes |
| Safety functions | Yes |
| Integral System Diagnostics, status | Yes |
Safety appraisal
| Standards | IEC 60947-5-3 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 4.00 x 10⁻⁹ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations |
| Hysteresis (Switch distance), maximum | 1.5 mm |
| Repeat accuracy R R | 0.5 mm |
| Latching force | 30 N |
| Actuating speed, maximum | 0.2 m/s |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 6.5 mm |
| Ensured switch distance ON Sao | 4 mm |
| Ensured switch distance OFF Sar | 30 mm |
Mechanical data - Connection technique
| Terminal Connector | Connector plug M12, 4-pole, (A-coding) |
Mechanical data - Dimensions
| Length of sensor | 50 mm |
| Width of sensor | 40 mm |
| Height of sensor | 220 mm |
Ambient conditions
| Degree of protection | IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +70 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Relative humidity, minimum | 30 % |
| Relative humidity, maximum | 95 % |
| Note (Relative humidity) | non-condensing |
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Operating Current | 50 mA |
Electrical data - AS Interface
| AS-i Operating voltage, minimum | 26.5 VDC |
| AS-i Operating voltage AS-i maximum | 31.6 VDC |
| Note (AS-i Operating voltage) | Protection against polarity reversal |
Electrical data - AS-Interface specification
| AS-i Version | V 2.1 |
| AS-i Profile | S-0.B.F.E |
| AS-i, IO-Code | 0x0 |
| AS-i, ID-Code | 0xB |
| AS-i, ID-Code1 | 0xF |
| AS-i, ID-Code2 | 0xE |
| AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
| AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
| AS-i Outputs, DO 0 … DO 3 | No Function |
| AS-i Parameter bits, P0 | Safety guard and actuator detected |
| AS-i Parameter bits, P1 | Safety release |
| AS-i Parameter bits, P2 | Static 0 |
| AS-i Parameter bits, P3 | Error |
| Note (AS-i Parameter bits) | Set the parameter outputs to '1111' (0xF) FID: periphery error |
| AS-i Input module address | 0 |
| Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
| Note (LED switching conditions display) | (1) LED green-red (AS-i Duo LED): Supply voltage / Communication error / Slave address = 0 (2) LED red: Internal device error (3) LED yellow: Device condition |
Pin assignment
| PIN 1 | AS-i + |
| PIN 2 | n.c. (≤ 30 VDC) |
| PIN 3 | AS-Interface - |
| PIN 4 | n.c. (≤ 30 VDC) |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |