- Actuator monitored
- Solenoid interlock
- Integrated AS-Interface
- Thermoplastic enclosure
- 90 mm x 84 mm x 30 mm
- Double-insulated
- High holding force
Ordering data
| Product type description | AZM 170 B ST-AS P | 
| Article number (order number) | 101210928 | 
| EAN (European Article Number) | 4030661390420 | 
| eCl@ss number, Version 9.0 | 27-27-26-03 | 
| eCl@ss number, Version 11.0 | 27-27-26-03 | 
Approval - Standards
| Certificates | TÜV cULus ASi-SaW EAC | 
General data
| Standards | IEC 61508 EN 60947-5-1 EN 62026-2 EN ISO 13849-1 | 
| Active principle | electromechanical | 
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | 
| Gross weight | 300 g | 
| Reaction time, maximum | 100 ms | 
General data - Features
| Power to unlock | Yes | 
| Actuator monitored | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of actuating directions | 2 | 
Safety appraisal
| Standards | IEC 61508 | |
| Performance level, up to | c | |
| Control category to EN13849 | 1 | |
| PFH-value | 1.16 x 10⁻⁶ /h | |
| Note (PFH-value) | up to max. 100,000 switching cycles/year | |
| 
 | 1 | |
| Mission Time | 20 Year(s) | 
Safety appraisal - Fault exclusion
| Please note: | Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist. | 
| Performance Level, up to | d | 
| Control category to EN13849 | 3 | 
| PFH-value | 1.01 x 10⁻⁷ /h | 
| Note (PFH-value) | up to max. 100,000 switching cycles/year | 
| Safety Integrity Level (SIL), suitable for applications in | 2 | 
| Mission time | 20 Year(s) | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
| Clamping force | 1,000 N | 
| Latching force | 5 N | 
| Actuating speed, maximum | 2 m/s | 
Mechanical data - Connection technique
| Terminal Connector | Connector plug M12, 4-pole, (A-coding) | 
Mechanical data - Dimensions
| Width of sensor | 90 mm | 
| Height of sensor | 75.5 mm | 
Ambient conditions
| Degree of protection | IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +55 °C | 
| Storage and transport temperature, minimum | -25 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Relative humidity, minimum | 30 % | 
| Relative humidity, maximum | 95 % | 
| Note (Relative humidity) | non-condensing non-icing | 
| Protection rating | II | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data - AS Interface
| AS-i Operating voltage, minimum | 26.5 VDC | 
| AS-i Operating voltage AS-i maximum | 31.6 VDC | 
| Note (AS-i Operating voltage) | Protection against polarity reversal | 
| AS-i Current consumption, maximum | 100 mA | 
Electrical data - AS-Interface specification
| AS-i Specification | Safety-Slave | 
| AS-i Version | V 2.1 | 
| AS-i Profile | S-7.B.F.E | 
| AS-i, IO-Code | 0x7 | 
| AS-i, ID-Code | 0xB | 
| AS-i, ID-Code1 | 0xF | 
| AS-i, ID-Code2 | 0xE | 
| AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission | 
| AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission | 
| AS-i Outputs, DO 0 | Solenoid control | 
| AS-i Outputs, DO 1 | No Function | 
| AS-i Outputs, DO 2 | No Function | 
| AS-i Outputs, DO 3 | No Function | 
| AS-i Parameter bits, P0 | Safety guard and actuator detected | 
| AS-i Parameter bits, P1 | Solenoid interlock locked | 
| AS-i Parameter bits, P2 | No function | 
| AS-i Parameter bits, P3 | No function | 
| Note (AS-i Parameter bits) | Set the parameter outputs to '1111' (0xF) FID: periphery error | 
| AS-i Input module address | 0 | 
| Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device | 
Electrical data - Auxiliary voltage
| Rated operating voltage | 24 VDC -15% / +10% (stabilised PELV) | 
| Operating current | 500 mA | 
Status indication
| Note (LED switching conditions display) | (1) LED green: Supply voltage (2) red LED: Communication error / Slave address = 0 (3) LED yellow : Enabling status | 
Pin assignment
| PIN 1 | AS-i + | 
| PIN 2 | Aux - (P) | 
| PIN 3 | AS-Interface - | 
| PIN 4 | Aux + (P) | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
Notes
| Note (General) | Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. | 
 
                

 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  