- AS-Interface M12 connector
- Thermoplastic enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 30 mm x 77 mm x 30 mm
- Actuator heads can be repositioned by 4 x 90°
- Mounting details to EN 50047
- AS-Interface LED and status display
- Integrated AS-Interface
- Suitable for AS-i Power24
- Lever angle adjustable in 10° steps
Ordering data
| Product type description | ZV14H 236 ST-AS |
| Article number (order number) | 103014405 |
| EAN (European Article Number) | 4030661496306 |
| eCl@ss number, Version 9.0 | 27-27-06-01 |
| eCl@ss number, Version 11.0 | 27-27-06-01 |
| ETIM number, version 6.0 | EC000030 |
| ETIM number, version 7.0 | EC000030 |
General data
| Standards | IEC 61508 EN 60947-5-1 EN 50295 EN ISO 13849-1 |
| Housing construction form | Norm construction design |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Material of the contacts, electrical | Silver |
| Lever material | Metal film |
| Roller material | Plastic |
| Gross weight | 107.5 g |
General data - Features
| Safety functions | Yes |
| Integral System Diagnostics, status | Yes |
| Number of auxiliary contacts | 0 |
| Number of safety contacts | 2 |
Safety appraisal
| Standards | IEC 61508 | |
| Performance level, up to | c | |
| Control category to EN13849 | 1 | |
| PFH-value | 1.14 x 10⁻⁶ /h | |
| Note (PFH-value) | up to max. 100,000 switching cycles/year | |
| 1 | |
| Mission Time | 20 Year(s) |
Safety appraisal - Fault exclusion
| Please note: | Einsetzbar wenn ein Fehlerausschluss für eine gefahrbringende Beschädigung der 1-kanaligen Mechanik zulässig ist und ein ausreichender Manipulationsschutz gewährleistet ist. |
| Performance Level, up to | d |
| Control category to EN13849 | 3 |
| PFH-value | 1.01 x 10⁻⁷ /h |
| Note (PFH-value) | up to max. 100,000 switching cycles/year |
| Safety Integrity Level (SIL), suitable for applications in | 2 |
| Mission time | 20 Year(s) |
Mechanical data
| Actuating element | Roller lever |
| Mechanical life, minimum | 1,000,000 Operations |
| Actuating speed, maximum | 1 m/s |
| Actuating torque, minimum | 0.2 Nm |
| Positive break torque | 0.2 Nm |
Mechanical data - Connection technique
| Terminal Connector | Connector plug M12, 4-pole |
| Material of the connector (electrical) | Plastic |
Mechanical data - Dimensions
| Length of sensor | 46 mm |
| Width of sensor | 30 mm |
| Height of sensor | 127.5 mm |
Ambient conditions
| Degree of protection | IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +60 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Relative humidity, minimum | 30 % |
| Relative humidity, maximum | 95 % |
| Note (Relative humidity) | non-condensing non-icing |
| Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 / 5 g |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
Electrical data
| Operating Current | 50 mA |
| Thermal test current | 10 A |
| Utilisation category AC-15 | 230 VAC |
| Utilisation category AC-15 | 4 A |
| Utilisation category DC-13 | 24 VDC |
| Utilisation category DC-13 | 1 A |
| Switching element | Opener (NC) |
| Switching principle | Snap switch element |
| Switching frequency | 5,000 /h |
Electrical data - AS Interface
| AS-i Operating voltage, minimum | 18 VDC |
| AS-i Operating voltage AS-i maximum | 31.6 VDC |
| Note (AS-i Operating voltage) | Protection against polarity reversal |
Electrical data - AS-Interface specification
| AS-i Version | V 3.0 |
| AS-i Profile | S-0.B.F.F |
| AS-i Input, Channel 1 | Data bits DI 0 / DI 1 = dynamic code transmission |
| AS-i Input, Channel 2 | Data bits DI 2 / DI 3 = dynamic code transmission |
| AS-i Outputs, DO 0 … DO 3 | No Function |
| AS-i Parameter bits, P0 | Channel 2 switched |
| AS-i Parameter bits, P1 ... P3 | No function |
| AS-i Input module address | 0 |
| Note (AS-i Input module address) | Preset to address 0, can be changed through AS-interface bus master or hand-held programming device |
Status indication
| Note (LED switching conditions display) | (1) LED yellow: Channel 1 / AS-i SaW Bit 0.1 (2) LED green-red (AS-i Duo LED):Supply voltage / Communication error / Slave address = 0 (3) LED yellow: Channel 2 / AS-i SaW Bit 2.3 |
Pin assignment
| PIN 1 | AS-Interface + |
| PIN 2 | n.c. |
| PIN 3 | AS-Interface - |
| PIN 4 | n.c. |
| PIN 5 | Functional earth connection |