- slim design
- 1 Cable entry M 20 x 1.5
- only for positioning tasks
- Design to EN 50041
- Thermoplastic enclosure
- Lever angle adjustable in 10° steps
- Double-insulated
- Good resistance to oil and petroleum spirit
- Wide range of alternative actuators
- Actuator heads can be repositioned by 4 x 90°
Ordering data
| Note (Delivery capacity) | Not available! |
| Product type description | T4V10H 336-20ZH |
| Article number (order number) | 101060464 |
| EAN (European Article Number) | 4030661481654 |
Approval - Standards
| Certificates | cULus CCC EAC |
General data
| Housing construction form | Norm construction design |
| Actuator type to DIN EN 50041 | D |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Material of the contacts, electrical | Silver |
| Lever material | Metal film |
| Material of the rod | Plastic |
| Gross weight | 165 g |
General data - Features
| Number of auxiliary contacts | 2 |
Safety appraisal
| Standards | BG-GS-ET-15 EN ISO 13849-1 EN 60947-5-1 |
| Mission Time | 20 Year(s) |
Mechanical data
| Actuating element | Rod lever |
| Mechanical life, minimum | 30,000,000 Operations |
| Actuating speed, maximum | 2.5 m/s |
| Note (Actuating speed) | Actuating speed with actuating angle 30° to switch axis |
| Note (Switchover time) | Switchover time in accordance with actuating speed |
| Actuating torque, minimum | 0.3 Nm |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable section, minimum | 0.75 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
Mechanical data - Dimensions
| Length x Width x Height | Height of sensor: 111.5 mm (without rod) |
| Length of sensor | 52 mm |
| Width of sensor | 40.5 mm |
Ambient conditions
| Ambient temperature, minimum | -30 °C |
| Ambient temperature, maximum | +80 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
| Thermal test current | 10 A |
| Required rated short-circuit current to EN 60947-5-1 | 1,000 A |
| Utilisation category AC-15 | 230 VAC |
| Utilisation category AC-15 | 4 A |
| Utilisation category DC-13 | 24 VDC |
| Utilisation category DC-13 | 4 A |
| Switching element | Normally open contact (NO) |
| Switching principle | Slow action with staggered contacts |
| Bounce duration, maximum | 2 ms |
| Switching frequency | 5,000 /h |
Notes
| Note (General) | Switch with 2 NO contacts are not for security tasks |