- Connector M12, 4-pole
- NOTICE: Not available! (Replacement: RSS16)
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Misaligned actuation possible
- 55 mm x 93 mm x 39.5 mm
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- Early warning when operating near the limit of the sensor's hysteris range
- Self-monitoring series-wiring of 16 sensors
- 2 short-circuit proof PNP safety outputs
Ordering data
| Note (Delivery capacity) | Not available! |
| Product type description | CSS 8-16-2P-E-LST |
| Article number (order number) | 101210575 |
| EAN (European Article Number) | 4030661388915 |
| eCl@ss number, Version 9.0 | 27-27-24-03 |
| eCl@ss number, Version 11.0 | 27-27-24-03 |
Approval - Standards
| Certificates | cULus EAC |
General data
| Standards | IEC 61508 IEC 60947-5-3 EN ISO 13849-1 |
| Active principle | inductive |
| Housing construction form | Block |
| Installation conditions (mechanical) | not flush |
| Sensor topology | Individual sensor or end sensor in a series |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Active area | Glass-fibre, reinforced thermoplastic |
| Gross weight | 285.5 g |
| Reaction time, maximum | 30 ms |
| Duration of risk, maximum | 30 ms |
General data - Features
| Short circuit detection | Yes |
| Short-circuit recognition | Yes |
| Safety functions | Yes |
| Integral System Diagnostics, status | Yes |
| Number of fail-safe digital outputs | 2 |
| Number of Series-wiring of sensors | 16 |
Safety appraisal
| Standards | IEC 60947-5-3 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 2.50 x 10⁻⁹ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Hysteresis (Switch distance), maximum | 1 mm |
| Repeat accuracy R R | 0.5 mm |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 8 mm |
| Ensured switch distance ON Sao | 6 mm |
| Ensured switch distance OFF Sar | 11 mm |
Mechanical data - Connection technique
| Terminal Connector | Cable with connector |
| Length of cable | 2 m |
| Terminal connector, Output | M12 connector, 4 pole |
Mechanical data - Dimensions
| Length of sensor | 39.5 mm |
| Width of sensor | 55 mm |
| Height of sensor | 93 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 IP67 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +55 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Voltage type | DC (direct current) |
| No-load supply current I0 | 50 mA |
| Rated operating voltage, minimum | 20.4 V |
| Rated operating voltage, maximum | 26.4 V |
| Operating current | 1,100 mA 500 mA |
| Note | Cable length and cable section alter the voltage drop depending on the output current |
| Switching frequency, approx. | 3 Hz |
Electrical data - Fail-safe digital outputs
| Output current, (fail-safe output), maximum | 0.5 A |
| Versions | p-type |
| Voltage drop Ud, maximum | 0.5 V |
| Current leakage Ir | 0.5 mA |
| Voltage, Utilisation category DC12 | 24 VDC |
| Current, Utilisation category DC12 | 0.5 A |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.5 A |
Electrical data - Diagnostic output
| Versions | p-type |
| Voltage drop Ud, maximum | 4 V |
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 |
| EMC rating | IEC 61000-6-2 |
Status indication
| Note (LED switching conditions display) | Multi-coloured LED: Green, Red, Yellow |
Pin assignment
| PIN 1 | 1A1 Ue: (1) |
| PIN 2 | Y2 Safety output 2 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |
Accessory
| Recommendation (actuator) | CST 16-1 |
| Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Notes
| Note (General) | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.25 ms. Short-circuit recognition by the evaluation is not necessary. |