- NOTICE: Not available!
- miniature body
- Safety type 4 in accordance with IEC 61496-1
- Resolution 30 mm
- Protection field height from 236 mm … 1804 mm
Ordering data
| Note (Delivery capacity) | Not available! |
| Product type description | SLC 430-E/R0236-30-RF-SYS |
| Article number (order number) | 101207674 |
| eCl@ss number, Version 9.0 | 27-27-27-04 |
| eCl@ss number, Version 11.0 | 27-27-27-04 |
General data
| Standards | IEC/EN 61496-1/-2 |
| Enclosure material | Aluminium |
| Gross weight | 1,300 g |
| Reaction time, maximum | 50 ms |
General data - Features
| Restart interlock (manual reset) | Yes |
| Beam coding available | Yes |
| Integral System Diagnostics, status | Yes |
| Integral System Diagnostics | Yes |
| Number of beams | 8 |
| Number of safety contacts | 2 |
Safety appraisal
| Standards | EN ISO 13849-1 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 1.26 x 10⁻⁸ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Detection ability for test bodies at v = 1.6 m/s | 30 mm |
| Height of the protection field | 236 mm |
| Range, protection field, minimum | 200 mm |
| Range, protection field, maximum | 3,500 mm |
| Wave length of the sensor | 880 nm |
Mechanical data - Connection technique
| Terminal Connector | Connector |
| Length of cable | 5 m |
| Terminal connector, Recipient | Cable with connector plug M8, 4-pole |
| Terminal, Connector, Transmitter | Cable with connector plug M8, 4-pole |
| Length of the connectable cable, maximum | 100 m |
Mechanical data - Dimensions
| Length of sensor | 20 mm |
| Width of sensor | 12 mm |
| Height of sensor | 468 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 |
| Ambient temperature, minimum | +0 °C |
| Ambient temperature, maximum | +50 °C |
| Storage and transport temperature, minimum | -10 °C |
| Storage and transport temperature, maximum | +70 °C |
| Protection rating | III |
Electrical data
| Voltage type | AC (alternating current) DC (direct current) |
| Switching voltage OSSD, HIGH signal | 24 V |
| Electrical power consumption of the receiver | 4 W |
| Electrical power consumption of the transmitter | 4 W |
Electrical data - Fail-safe digital outputs
| Output current, (fail-safe output), maximum | 4 A |
| Versions | p-type |
Scope of delivery
| Included in delivery | Emitter + receiver, mounting angle |
Accessory
| Recommended safety switchgear | NSR-0605 |
Notes
| Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |