- NOTICE: Not available! (Replacement: SLC 425I)
- Control Category 4
Ordering data
| Note (Delivery capacity) | Not available! |
| Product type description | SLC 415I-E/R1510-90-12 |
| Article number (order number) | 101170451 |
| eCl@ss number, Version 9.0 | 27-27-27-04 |
| eCl@ss number, Version 11.0 | 27-27-27-04 |
General data
| Standards | IEC/EN 61496-1/-2 |
| Enclosure material | Aluminium |
| Reaction time, maximum | 13.5 ms |
General data - Features
| Muting function | Yes |
| Override | Yes |
| Restart interlock (manual reset) | Yes |
| Beam coding available | Yes |
| Integral System Diagnostics, status | Yes |
| Integral System Diagnostics | Yes |
| Number of beams | 21 |
| Number of fail-safe digital outputs | 2 |
Safety appraisal
| Safety type in accordance with IEC 61496-1 | 4 |
Mechanical data
| Detection ability for test bodies at v = 1.6 m/s | 90 mm |
| Height of the protection field | 1,510 mm |
| Range, protection field, minimum | 0 mm |
| Range, protection field, maximum | 16,000 mm |
| Wave length of the sensor | 950 nm |
Mechanical data - Connection technique
| Terminal Connector | Connector |
| Terminal connector, Recipient | Connector plug M23, 19-pole |
| Terminal, Connector, Transmitter | Connector plug M12, 5-pole |
| Length of the connectable cable, maximum | 100 m |
Mechanical data - Dimensions
| Length of sensor | 50 mm |
| Width of sensor | 60 mm |
| Height of sensor | 1,636 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 |
| Ambient temperature, minimum | +0 °C |
| Ambient temperature, maximum | +55 °C |
| Storage and transport temperature, minimum | -20 °C |
| Storage and transport temperature, maximum | +70 °C |
| Protection rating | III |
Electrical data
| Voltage type | DC (direct current) |
| Switching voltage OSSD, HIGH signal | 24 V |
| Electrical power consumption of the receiver | 6 W |
| Electrical power consumption of the transmitter | 3 W |
Electrical data - Fail-safe digital outputs
| Output current, (fail-safe output), maximum | 0.5 A |
| Versions | p-type |
Scope of delivery
| Included in delivery | Emitter + receiver, mounting angle, T-slot nuts |
Accessory
| Recommended safety switchgear | SCR 402R-301 |
Notes
| Note (General) | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 0.3 mA. 2 or 4 muting sensors can be connected. The muting sensors (e.g. LF 50) must be ordered separately. |