- Repeated individual coding with RFID technology
- Coding level 'High' according to ISO 14119
- Connector M12, 8-pole
- Diagnostic output
- Individual coding
- Suitable for mounting to profile systems
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Compact design
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
Ordering data
| Note (Delivery capacity) | Not available! | 
| Product type description | AZ300-I2-ST-1P2P | 
| Article number (order number) | 103001466 | 
| EAN (European Article Number) | 4030661435831 | 
| eCl@ss number, Version 9.0 | 27-27-26-02 | 
| eCl@ss number, Version 11.0 | 27-27-26-02 | 
Approval - Standards
| Certificates | TÜV cULus ECOLAB EAC FCC IC | 
General data
| Standards | IEC 61508 IEC 60947-5-3 EN 60947-5-1 EN ISO 13849-1 | 
| general information | Individual coding, multiple teaching | 
| Coding level according to ISO 14119 | High | 
| Active principle | RFID | 
| Enclosure material | Glass-fibre, reinforced thermoplastic | 
| Gross weight | 528 g | 
| Time to readiness, maximum | 5,000 ms | 
| Reaction time, maximum | 100 ms | 
| Duration of risk, maximum | 200 ms | 
General data - Features
| Actuator monitored | Yes | 
| Latching | Yes | 
| Short circuit detection | Yes | 
| Short-circuit recognition | Yes | 
| Series-wiring | Yes | 
| Safety functions | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of safety contacts | 2 | 
Safety appraisal
| Standards | IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 5.20 x 10⁻¹⁰ /h | |
| 
 | 3 | |
| Mission Time | 20 Year(s) | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
| Note (Mechanical lifetime) | > 50,000 operations for door weights ≤ 5 kg Actuating speed ≤ 0.5 m/s | 
| Latching force, adjustable, position 1 | 25 N | 
| Latching force, adjustable, position 2 | 50 N | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 2 mm | 
| Ensured switch distance ON Sao | 1 mm | 
| Ensured switch distance OFF Sar | 20 mm | 
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole, A-coded | 
Mechanical data - Dimensions
| Length of sensor | 35 mm | 
| Width of sensor | 85 mm | 
| Height of sensor | 100 mm | 
Ambient conditions
| Degree of protection | IP66 to EN 60529 IP67 to EN 60529 IP69K to DIN 40050-9 | 
| Ambient temperature, minimum | +0 °C | 
| Ambient temperature, maximum | +60 °C | 
| Storage and transport temperature, minimum | -10 °C | 
| Storage and transport temperature, maximum | +90 °C | 
| Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm | 
| Restistance to shock | 30 g / 11 ms | 
| Protection rating | II | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data
| Current consumption at 24V | 5 mA | 
| No-load supply current I0 | 100 mA | 
| Operating current | 50 mA | 
| Required rated short-circuit current to EN 60947-5-1 | 100 A | 
| Note | Cable length and cable section alter the voltage drop depending on the output current | 
| Switching frequency, approx. | 0.5 Hz | 
Electrical data - Fail-safe digital inputs
| Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) | 
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA | 
| Voltage drop Ud, maximum | 4 V | 
| Current leakage Ir | 0.5 mA | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.25 A | 
Electrical data - Diagnostic output
| Versions | short-circuit proof, p-type | 
| Voltage drop Ud, maximum | 4 V | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.05 A | 
Status indication
| Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green | 
Pin assignment
| PIN 1 | A1 Supply voltage UB | 
| PIN 2 | X1 Safety input 1 | 
| PIN 3 | A2 GND | 
| PIN 4 | Y1 Safety output 1 | 
| PIN 5 | OUT Diagnostic output | 
| PIN 6 | X2 Safety input 2 | 
| PIN 7 | Y2 Safety output 2 | 
| PIN 8 | without function | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
| Delivery scope of Mounting material | 2 x M6 | 
Accessory
| Recommendation (actuator) | AZ/AZM300-B1 | 
Notes
| Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. | 
 
                



 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  