- Universal coding with RFID technology
- Connector M12, 8-pole
- Diagnostic output
- Suitable for mounting to profile systems
- Thermoplastic enclosure
- RFID-technology for needs-based protection against tampering
- 3 different directions of actuation
- Compact design
- 3 LEDs to show operating conditions
- Suitable for hinged and sliding guards
- Series-wiring
Ordering data
| Note (Delivery capacity) | Not available! |
| Product type description | AZ300-ST-1P2P |
| Article number (order number) | 103001462 |
| EAN (European Article Number) | 4030661435862 |
| eCl@ss number, Version 9.0 | 27-27-26-02 |
| eCl@ss number, Version 11.0 | 27-27-26-02 |
Approval - Standards
| Certificates | TÜV cULus ECOLAB EAC FCC IC |
General data
| Standards | IEC 61508 IEC 60947-5-3 EN 60947-5-1 EN ISO 13849-1 |
| general information | Universal coding |
| Coding level according to ISO 14119 | Low |
| Active principle | RFID |
| Enclosure material | Glass-fibre, reinforced thermoplastic |
| Gross weight | 250 g |
| Time to readiness, maximum | 5,000 ms |
| Reaction time, maximum | 100 ms |
| Duration of risk, maximum | 200 ms |
General data - Features
| Actuator monitored | Yes |
| Latching | Yes |
| Short circuit detection | Yes |
| Short-circuit recognition | Yes |
| Series-wiring | Yes |
| Safety functions | Yes |
| Integral System Diagnostics, status | Yes |
| Number of safety contacts | 2 |
Safety appraisal
| Standards | IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 5.20 x 10⁻¹⁰ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations |
| Note (Mechanical lifetime) | > 50,000 operations for door weights ≤ 5 kg Actuating speed ≤ 0.5 m/s |
| Latching force, adjustable, position 1 | 25 N |
| Latching force, adjustable, position 2 | 50 N |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 2 mm |
| Ensured switch distance ON Sao | 1 mm |
| Ensured switch distance OFF Sar | 20 mm |
Mechanical data - Connection technique
| Terminal Connector | Connector M12, 8-pole, A-coded |
Mechanical data - Dimensions
| Length of sensor | 35 mm |
| Width of sensor | 85 mm |
| Height of sensor | 100 mm |
Ambient conditions
| Degree of protection | IP66 to EN 60529 IP67 to EN 60529 IP69K to DIN 40050-9 |
| Ambient temperature, minimum | +0 °C |
| Ambient temperature, maximum | +60 °C |
| Storage and transport temperature, minimum | -10 °C |
| Storage and transport temperature, maximum | +90 °C |
| Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Current consumption at 24V | 5 mA |
| No-load supply current I0 | 100 mA |
| Operating current | 50 mA |
| Required rated short-circuit current to EN 60947-5-1 | 100 A |
| Note | Cable length and cable section alter the voltage drop depending on the output current |
| Switching frequency, approx. | 0.5 Hz |
Electrical data - Fail-safe digital inputs
| Switching thresholds | −3 V … 5 V (Low) 15 V … 30 V (High) |
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA |
| Voltage drop Ud, maximum | 4 V |
| Current leakage Ir | 0.5 mA |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.25 A |
Electrical data - Diagnostic output
| Versions | short-circuit proof, p-type |
| Voltage drop Ud, maximum | 4 V |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.05 A |
Status indication
| Note (LED switching conditions display) | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
Pin assignment
| PIN 1 | A1 Supply voltage UB |
| PIN 2 | X1 Safety input 1 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | OUT Diagnostic output |
| PIN 6 | X2 Safety input 2 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | without function |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |
| Delivery scope of Mounting material | 2 x M6 |
Accessory
| Recommendation (actuator) | AZ/AZM300-B1 |
Notes
| Note (General) | For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used. For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used. |