- 1 Cable entry M 20 x 1.5
- Thermoplastic enclosure
- AC 2-wire
- Double-insulated
- Wiring compartment
- Design 333
Ordering data
| Product type description | IFL 20-333-10/01-M20 | 
| Article number (order number) | 101173574 | 
| EAN (European Article Number) | 4030661302737 | 
| eCl@ss number, Version 9.0 | 27-27-01-01 | 
| eCl@ss number, Version 11.0 | 27-27-01-01 | 
| ETIM number, version 6.0 | EC002714 | 
| ETIM number, version 7.0 | EC002714 | 
Approval - Standards
| Certificates | CCC | 
General data
| Standards | IEC/EN 60947-5-2 DIN VDE 0660-208 | 
| Housing construction form | Block | 
| Installation conditions (mechanical) | not flush | 
| Enclosure material | Plastic | 
| Material of the cover | Luran | 
| Gross weight | 170 g | 
General data - Features
| Integral System Diagnostics, status | Yes | 
| Number of cable wires | 2 | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 20 mm | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, maximum | 2 x 1.5 mm² | 
Mechanical data - Dimensions
| Length of sensor | 112 mm | 
| Width of sensor | 40 mm | 
| Height of sensor | 40 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +70 °C | 
| Protection rating | II | 
Ambient conditions - Insulation value
| Rated impulse withstand voltage Uimp | 4 kV | 
Electrical data
| Voltage type | AC (alternating current) | 
| Rated supply frequency, minimum | 45 Hz | 
| Rated supply frequency, maximum | 65 Hz | 
| Operating voltage, minimum | 15 V | 
| Operating voltage, maximum | 250 V | 
| Operating current, minimum | 10 mA | 
| Operating current | 500 mA | 
| Switching element | NO contact or NC contact | 
| Protection circuit integrated | inductive interference protection | 
| Switching frequency, approx. | 10 Hz | 
Electrical data - Digital Output
| Voltage drop Ud, maximum | 4.5 V | 
| Current at Voltage drop Ud | 0.2 A | 
| Versions | Two-wire | 
| Current leakage Ir | 1 mA | 
Status indication
| Note (Integral System Diagnostics, status ) | yellow LED | 
Notes
| Note (General) | Programmable by repositioning the plug-in jumper at the terminal screws By repositioning the switch 5 different actuating directions can be selected. The selected actuating direction can be marked with a sticker. | 
 
                



 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                
 
                   
                   
                  