- Snap action with constant contact pressure up to switching point
- Ex certified
- Metal enclosure
- Wide range of alternative actuators
- Good resistance to oil and petroleum spirit
- 30 mm x 63,5 mm x 30 mm
- Actuator heads can be repositioned by 4 x 90°
- Mounting details to EN 50047
- Ex-certified screwed cable gland
- 1 Cable entry M 20 x 1.5
- Actuation from bottom parallel to the switch, therefore only suitable for small housings.
Ordering data
| Product type description | EX-Z4K 235-11Z-3D | 
| Article number (order number) | 103001802 | 
| eCl@ss number, Version 9.0 | 27-27-26-01 | 
Approval - Standards
| Certificates | INMETRO | 
Explosion protection
| Explosion protection: regulations | EN 60079-15 EN 60079-31 IEC 60079-0 | 
| Explosion protection zones | 22 2 | 
| Explosion protection category | 3D 3G | 
| Explosion protection designation | D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X | 
| Manufacturer declaration | ATEX Zone 2 and 22 | 
General data
| Standards | EN 60947-5-1 BG-GS-ET-15 | 
| Housing construction form | Norm construction design | 
| Enclosure material | Zink | 
| Enclosure coating material | painted | 
| Material of the contacts, electrical | Silver | 
General data - Features
| Safety functions | Yes | 
| Number of auxiliary contacts | 1 | 
| Number of safety contacts | 1 | 
Safety appraisal
| Standards | EN ISO 13849-1 | 
| Mission Time | 20 Year(s) | 
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 20,000,000 Operations | 
Mechanical data
| Actuating element | Angle roller lever | 
| Mechanical life, minimum | 20,000,000 Operations | 
| Actuating force, minimum | 6 N | 
| Positive break force, minimum | 16 N | 
| Actuating speed, minimum | 44 mm/min | 
| Actuating speed, maximum | 1 m/s | 
| Note (Actuating speed) | Actuating speed with actuating angle 30° to switch axis | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable cross-section of the cable glands, minimum | 6 mm | 
| Cable cross-section of the cable glands, maximum | 12 mm | 
| Cable section, minimum | 0.75 mm² | 
| Cable section, maximum | 2.5 mm² | 
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. | 
| Wire cross-section | 13 AWG | 
Mechanical data - Dimensions
| Length of sensor | 30 mm | 
| Width of sensor | 42 mm | 
| Height of sensor | 107 mm | 
Ambient conditions
| Degree of protection | IP67 | 
| Ambient temperature, minimum | -20 °C | 
| Ambient temperature, maximum | +60 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 500 V | 
| Rated impulse withstand voltage Uimp | 6 kV | 
Electrical data
| Thermal test current | 10 A | 
| Utilisation category AC-15 | 230 VAC | 
| Utilisation category AC-15 | 4 A | 
| Utilisation category DC-13 | 24 VDC | 
| Utilisation category DC-13 | 1 A | 
| Switching element | NO contact, NC contact | 
| Switching principle | Snap switch element | 
| Bounce duration, maximum | 3 ms | 
| Switching frequency | 5,000 /h | 
| Switchover time, maximum | 5.5 ms | 
 
                





 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                
 
                   
                   
                  