- IDC method of termination
- Manual release
- Explosion protection for ATEX Zones 2 and 22
- Thermoplastic enclosure
- 1 Cable entry M 20 x 1.5
- Interlock with protection against incorrect locking.
- High holding force
- 90 mm x 84 mm x 30 mm
Ordering data
| Product type description | EX-AZM 170-02ZRKA 24VAC/DC-3G/D | 
| Article number (order number) | 101194966 | 
| EAN (European Article Number) | 4030661360010 | 
| eCl@ss number, Version 9.0 | 27-27-26-03 | 
| eCl@ss number, Version 11.0 | 27-27-26-03 | 
Explosion protection
| Explosion protection: regulations | BG-GS-ET-19 EN 60079-0 EN 60079-15 EN 60079-31 EN 60947-5-1 | 
| Explosion protection zones | 22 2 | 
| Explosion protection category | 3D 3G | 
| Explosion protection designation | D II 3G Ex nC IIB T5 Gc X D II 3D Ex tc IIIC T80°C Dc X | 
| Manufacturer declaration | ATEX Zone 2 and 22 | 
General data
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing | 
| Material of the contacts, electrical | Silver | 
| Gross weight | 289 g | 
General data - Features
| Power to lock | Yes | 
| Manual release | Yes | 
| Number of safety contacts | 2 | 
Safety appraisal
| Standards | EN ISO 13849-1 | 
| Mission Time | 20 Year(s) | 
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations | 
Mechanical data
| Mechanical life, minimum | 1,000,000 Operations | 
| Impact energy, maximum | 1 J | 
| Clamping force | 1,000 N | 
| Latching force | 30 N | 
| positive break travel | 11 mm | 
| Positive break force, minimum | 17 N | 
| Actuating speed, maximum | 1 m/s | 
Mechanical data - Connection technique
| Terminal Connector | IDC method of termination | 
| Cable cross-section of the cable glands, minimum | 6.5 mm | 
| Cable cross-section of the cable glands, maximum | 12 mm | 
| Cable section, minimum | 2 x 1.0 mm², flexible | 
| Cable section, maximum | 1 x 1 mm², flexible | 
Mechanical data - Dimensions
| Length of sensor | 30 mm | 
| Width of sensor | 90 mm | 
| Height of sensor | 84 mm | 
Ambient conditions
| Degree of protection | IP67 to EN 60529 | 
| Ambient temperature, minimum | -15 °C | 
| Ambient temperature, maximum | +45 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 250 V | 
| Rated impulse withstand voltage Uimp | 4 kV | 
Electrical data
| Thermal test current | 2 A | 
| Rated control voltage | 24 VAC | 
| Rated control voltage | 24 VDC | 
| Utilisation category AC-15 | 230 VAC | 
| Utilisation category AC-15 | 2 A | 
| Utilisation category DC-13 | 24 VDC | 
| Utilisation category DC-13 | 2 A | 
| Electrical power consumption, maximum | 10 W | 
| Switching element | Opener (NC) | 
| Switching principle | Creep circuit element | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. Including Ex-certified screwed cable gland and screw plug | 
Notes
| Note (General) | This type termination (IDC) method enables simple connetion of flexible conductors without the need for the use of conductor ferrules | 
| Note (Manual release) | bottom For manual release using M5 triangular key, available as accessory | 
 
                





 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                
 
                   
                   
                  