- 2 cable entries M 20 x 1.5
- Metal enclosure
- 118 mm x 155 mm x 64 mm ( basic component)
- Actuator can be repositioned by 90°
Ordering data
| Product type description | TR 461-03Y |
| Article number (order number) | 101058828 |
| EAN (European Article Number) | 4030661033938 |
| eCl@ss number, Version 9.0 | 27-27-06-01 |
| eCl@ss number, Version 11.0 | 27-27-06-01 |
| ETIM number, version 6.0 | EC000030 |
| ETIM number, version 7.0 | EC000030 |
Approval - Standards
| Certificates | DNV.GL EAC |
General data
| Standards | EN 60947-5-1 |
| Active principle | mechanical |
| Slide form | Castor |
| Enclosure material | Grey cast iron, galvanised |
| Enclosure coating material | painted |
| Material of the contacts, electrical | Silver |
| Roller material | Plastic |
| Gross weight | 1,960 g |
General data - Features
| Number of openers | 3 |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations |
Mechanical data
| Actuating element | Roller plunger |
| Mechanical life, minimum | 10,000,000 Operations |
| Actuating angle, from left of switch axis | 30 ° |
| Actuating angle, from right of switch axis | 30 ° |
| Contact opening | max. 2 x 6 mm |
| Actuating speed, minimum | 1 mm/min |
| Actuating speed, maximum | 0.5 m/s |
| Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis |
Mechanical data - Connection technique
| Terminal Connector | Screw connection |
| Cable section, minimum | 1.5 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. |
| Wire cross-section | 13 AWG |
Mechanical data - Dimensions
| Length of sensor | 64 mm |
| Width of sensor | 118 mm |
| Height of sensor | 201 mm |
| Width of Castor | 6.5 mm |
| Diameter of Castor | 25 mm |
Ambient conditions
| Degree of protection | IP65 to EN 60529 |
| Ambient temperature, minimum | -30 °C |
| Ambient temperature, maximum | +90 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 400 V |
| Rated impulse withstand voltage Uimp | 6 kV |
Electrical data
| Thermal test current | 16 A |
| Utilisation category AC-15 | 400 VAC |
| Utilisation category AC-15 | 4 A |
| Switching element | Opener (NC) |
| Note (Switching element) | with double break |
| Switching principle | Creep circuit element |
