- 2 cable entries M 20 x 1.5
- Metal enclosure
- 1 Contact
- 106 mm x 71 mm x 63 mm (basic component)
- Protection class IP65
Ordering data
| Product type description | TS 422-01Y | 
| Article number (order number) | 101058334 | 
| EAN (European Article Number) | 4030661032108 | 
| eCl@ss number, Version 9.0 | 27-27-06-01 | 
| eCl@ss number, Version 11.0 | 27-27-06-01 | 
| ETIM number, version 6.0 | EC000030 | 
| ETIM number, version 7.0 | EC000030 | 
Approval - Standards
| Certificates | DNV.GL CCC EAC | 
General data
| Standards | EN 60947-5-1 | 
| Active principle | mechanical | 
| Slide form | Sphere | 
| Enclosure material | Grey cast iron, galvanised | 
| Enclosure coating material | painted | 
| Material of the contacts, electrical | Silver | 
| Gross weight | 970 g | 
General data - Features
| Number of openers | 1 | 
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) | 2,000,000 Operations | 
Mechanical data
| Actuating element | Plunger | 
| Mechanical life, minimum | 10,000,000 Operations | 
| Actuating angle | 20 ° | 
| Contact opening | 2 x 6 mm | 
| Actuating speed, minimum | 1 mm/min | 
| Actuating speed, maximum | 1 m/s | 
| Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, minimum | 1.5 mm² | 
| Cable section, maximum | 2.5 mm² | 
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. | 
| Wire cross-section | 13 AWG | 
Mechanical data - Dimensions
| Length of sensor | 63 mm | 
| Width of sensor | 106 mm | 
| Height of sensor | 97 mm | 
| Diameter of the Plunger | 10 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 | 
| Ambient temperature, minimum | -30 °C | 
| Ambient temperature, maximum | +90 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 400 V | 
Electrical data
| Thermal test current | 16 A | 
| Utilisation category AC-15 | 400 VAC | 
| Utilisation category AC-15 | 4 A | 
| Switching element | Opener (NC) | 
| Note (Switching element) | with double break | 
| Switching principle | Creep circuit element | 
Notes
| Note (General) | Actuation from the side of the plunger should be avoided, since this reduces the mechanical life of the position switch. | 
 
                




 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  