- Metal enclosure
- Actuator head can be repositioned in steps 4 x 90°
- Continuous adjustment of lever position 360°
- Lever can be transposed by 180°
- 3 Contacts
- 62 mm x 105 mm x 50 mm ( basic component)
- Switching points and contact function adjustable
- 3 cable entries M 20 x 1.5
Ordering data
| Product type description | UV7H 433Y | 
| Article number (order number) | 101060585 | 
| EAN (European Article Number) | 4030661047683 | 
| eCl@ss number, Version 9.0 | 27-27-06-01 | 
| eCl@ss number, Version 11.0 | 27-27-06-01 | 
| ETIM number, version 6.0 | EC000030 | 
| ETIM number, version 7.0 | EC000030 | 
Approval - Standards
| Certificates | cULus EAC | 
General data
| Standards | EN 60947-5-1 | 
| Active principle | mechanical | 
| Slide form | Castor | 
| Enclosure material | Light alloy die-casting | 
| Enclosure coating material | painted | 
| Material of the contacts, electrical | Silver | 
| Roller material | Plastic | 
| Gross weight | 565 g | 
General data - Features
| Number of openers | 3 | 
Mechanical data
| Actuating element | Roller lever | 
| Mechanical life, minimum | 10,000,000 Operations | 
| Actuating angle, from left of switch axis | 30 ° | 
| Actuating angle, from right of switch axis | 30 ° | 
| Contact opening | 2 x 1.5 mm | 
| Actuating speed, minimum | 1 mm/min | 
| Actuating speed, maximum | 3 m/s | 
| Note (Actuating speed) | Actuating speed with vertical actuating angle to switch axis | 
Mechanical data - Connection technique
| Terminal Connector | Screw connection | 
| Cable section, minimum | 1.5 mm² | 
| Cable section, maximum | 2.5 mm² | 
| Note (Cable section) | All indications about the cable section are including the conductor ferrules. | 
| Wire cross-section | 13 AWG | 
Mechanical data - Dimensions
| Length of sensor | 50 mm | 
| Width of sensor | 62 mm | 
| Height of sensor | 240 mm | 
| Width of Castor | 9 mm | 
| Diameter of Castor | 36 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 | 
| Ambient temperature, minimum | -20 °C | 
| Ambient temperature, maximum | +60 °C | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 500 V | 
Electrical data
| Thermal test current | 16 A | 
| Switching element | Opener (NC) | 
| Switching principle | Creep circuit element | 
Notes
| Note (General) | Type of contact and switching points can be factory set to order. | 
 
                






 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  