- serial diagnostic output
- Stainless steel enclosure
- Max. 31 sensors can be wired in series.
- Connector M12, 8-pole
- Ø M30
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
- Safety sensor can also be installed behind V4A covers.
Ordering data
| Product type description | CSS 11-30S-SD-M-ST |
| Article number (order number) | 101204613 |
| EAN (European Article Number) | 4030661381657 |
| eCl@ss number, Version 9.0 | 27-27-24-03 |
| eCl@ss number, Version 11.0 | 27-27-24-03 |
Approval - Standards
| Certificates | TÜV cULus EAC |
General data
| Standards | IEC 61508 IEC 60947-5-3 |
| Active principle | inductive |
| Housing construction form | Cylinder, thread |
| Installation conditions (mechanical) | not flush |
| Sensor topology | Sensor for series wiring |
| Enclosure material | Stainless steel |
| Gross weight | 248 g |
| Reaction time, maximum | 60 ms |
| Duration of risk, maximum | 60 ms |
General data - Features
| Serial diagnostics | Yes |
| Diagnostic output | Yes |
| Short circuit detection | Yes |
| Short-circuit recognition | Yes |
| Safety functions | Yes |
| Cascadable | Yes |
| Integral System Diagnostics, status | Yes |
| Number of LEDs | 2 |
| Number of semi-conductor outputs with signaling function | 1 |
| Number of fail-safe digital outputs | 2 |
| Number of Series-wiring of sensors | 31 |
Safety appraisal
| Standards | EN ISO 13849-1 IEC 60947-5-3 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 3.60 x 10⁻⁹ /h | |
| 3 | |
| Mission Time | 20 Year(s) |
Mechanical data
| Actuating panels | Actuation from top |
| Active area | front side |
| Hysteresis (Switch distance), maximum | 2 mm |
| Repeat accuracy R R | 1 mm |
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 11 mm |
| Ensured switch distance ON Sao | 8 mm |
| Ensured switch distance OFF Sar | 15 mm |
Mechanical data - Connection technique
| Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current |
Mechanical data - Dimensions
| ISO thread of the sensor | M30 |
| Length of sensor | 99.5 mm |
Ambient conditions
| Degree of protection | IP69 to EN 60529 |
| Ambient temperature, minimum | -25 °C |
| Ambient temperature, maximum | +65 °C |
| Storage and transport temperature, minimum | -25 °C |
| Storage and transport temperature, maximum | +85 °C |
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm |
| Restistance to shock | 30 g / 11 ms |
| Protection rating | II |
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VAC/DC |
| Rated impulse withstand voltage Uimp | 0.8 kV |
| Overvoltage category | III |
| Degree of pollution to VDE 0100 | 3 |
Electrical data
| Voltage type | DC (direct current) |
| No-load supply current I0 | 100 mA |
| Rated operating voltage, minimum | 20.4 VDC |
| Rated operating voltage, maximum | 26.4 VDC |
| Operating current | 600 mA |
| Required rated short-circuit current to EN 60947-5-1 | 100 A |
| Switching frequency, approx. | 3 Hz |
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA |
| Output current, (fail-safe output), maximum | 0.25 A |
| Versions | p-type |
| Voltage drop Ud, maximum | 0.5 V |
| Current leakage Ir | 0.5 mA |
| Voltage, Utilisation category DC12 | 24 VDC |
| Current, Utilisation category DC12 | 0.25 A |
| Voltage, Utilisation category DC13 | 24 VDC |
| Current, Utilisation category DC13 | 0.25 A |
Electrical data - Diagnostic output
| Operating current | 150 mA |
| Versions | p-type |
| Voltage drop Ud, maximum | 5 V |
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 |
| EMC rating | IEC 61000-6-2 |
Pin assignment
| PIN 1 | 1A1 Ue: (1) |
| PIN 2 | X1 Safety input 1 |
| PIN 3 | A2 GND |
| PIN 4 | Y1 Safety output 1 |
| PIN 5 | SD serial diagnostic output |
| PIN 6 | X2 Safety input 2 |
| PIN 7 | Y2 Safety output 2 |
| PIN 8 | IN serial diagnostic input |
Scope of delivery
| Included in delivery | Actuators must be ordered separately. |
| Delivery scope of Mounting material | 2x Mounting material M30 x 1.5 nuts |
Accessory
| Recommendation (actuator) | CST 30S-1 |
| Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
Notes
| Note (General) | Evaluation requirements: The switch-off pauses of 250 µs – 1500 µs must be tolerated by the evaluation. |