- 1 x connector plug M12, 8-pole
- Actuation from side
- serial diagnostic output
- Max. 31 sensors can be wired in series.
- Thermoplastic enclosure
- Electronic contact-free, coded system
- Misaligned actuation possible
- 27 mm x 108.2 mm x 35 mm
- High repeat accuracy of the switching points
- Max. length of the sensor chain 200 m
- 2 short-circuit proof PNP safety outputs
- Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet
Ordering data
| Product type description | CSS 14-34-S-SD-M-ST | 
| Article number (order number) | 101181066 | 
| EAN (European Article Number) | 4030661314891 | 
| eCl@ss number, Version 9.0 | 27-27-24-03 | 
| eCl@ss number, Version 11.0 | 27-27-24-03 | 
Approval - Standards
| Certificates | TÜV cULus EAC | 
General data
| Standards | IEC 60947-5-3 | 
| Active principle | inductive | 
| Housing construction form | Block | 
| Installation conditions (mechanical) | not flush | 
| Sensor topology | Sensor for series wiring | 
| Enclosure material | Glass-fibre, reinforced thermoplastic | 
| Active area | Glass-fibre, reinforced thermoplastic | 
| Gross weight | 140 g | 
| Reaction time, maximum | 30 ms | 
| Duration of risk, maximum | 60 ms | 
General data - Features
| Serial diagnostics | Yes | 
| Diagnostic output | Yes | 
| Short circuit detection | Yes | 
| Short-circuit recognition | Yes | 
| Safety functions | Yes | 
| Cascadable | Yes | 
| Integral System Diagnostics, status | Yes | 
| Number of LEDs | 3 | 
| Number of semi-conductor outputs with signaling function | 1 | 
| Number of fail-safe digital outputs | 2 | 
| Number of Series-wiring of sensors | 31 | 
Safety appraisal
| Standards | EN ISO 13849-1 IEC 60947-5-3 IEC 61508 | |
| Performance level, up to | e | |
| Control category to EN13849 | 4 | |
| PFH-value | 3.60 x 10⁻⁹ /h | |
| 
 | 3 | |
| Mission Time | 20 Year(s) | 
Mechanical data
| Actuating panels | lateral | 
| Active area | lateral | 
| Actuator switch distance | Actuator CST 180-1 / CST 180-2: 10 mm Actuator CST 34-S-1: 14 mm Actuator CST 34-S-2: 14 mm Actuator CST 34-S-3: 14 mm Actuator CST 34-S-1: 12 mm Actuator CST 34-S-2: 12 mm Actuator CST 34-S-3: 12 mm Actuator CST 180-1 / CST 180-2: 8 mm Actuator CST 34-S-1: 17 mm Actuator CST 34-S-2: 17 mm Actuator CST 34-S-3: 17 mm Actuator CST 180-1 / CST 180-2: 13 mm | 
| Hysteresis (Switch distance), maximum | 1.5 mm | 
| Repeat accuracy R R | 0.5 mm | 
| Note (Repeat accuracy R) | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 36 mm (e.g. mounting tolerance or due to guard door sagging). Increased misalignment, max. 53 mm, possible when the CST 34-S-2 actuator is used. The axial misalignment (y) is max. ± 10 mm (see figure: Operating principle) | 
Mechanical data - Switching distances according IEC 60947-5-3
| Switch distance | 10 mm 14 mm | 
| Ensured switch distance ON Sao | 12 mm 8 mm | 
| Ensured switch distance OFF Sar | 13 mm 17 mm | 
Mechanical data - Connection technique
| Terminal Connector | Connector plug M12, 8-pole | 
| Note | The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current | 
Mechanical data - Dimensions
| Length of sensor | 35 mm | 
| Width of sensor | 27 mm | 
| Height of sensor | 108.2 mm | 
Ambient conditions
| Degree of protection | IP65 to EN 60529 IP67 to EN 60529 | 
| Ambient temperature, minimum | -25 °C | 
| Ambient temperature, maximum | +70 °C | 
| Storage and transport temperature, minimum | -25 °C | 
| Storage and transport temperature, maximum | +85 °C | 
| Resistance to vibrations to EN 60068-2-6 | 10 … 55 Hz, amplitude 1 mm | 
| Restistance to shock | 30 g / 11 ms | 
| Protection rating | II | 
Ambient conditions - Insulation value
| Rated insulation voltage Ui | 32 VDC | 
| Rated impulse withstand voltage Uimp | 0.8 kV | 
| Overvoltage category | III | 
| Degree of pollution to VDE 0100 | 3 | 
Electrical data
| Voltage type | DC (direct current) | 
| No-load supply current I0 | 100 mA | 
| Operating current | 600 mA | 
| Required rated short-circuit current to EN 60947-5-1 | 100 A | 
| Switching frequency, approx. | 3 Hz | 
Electrical data - Fail-safe digital outputs
| Rated operating current (safety outputs) | 250 mA | 
| Output current, (fail-safe output), maximum | 0.25 A | 
| Versions | p-type | 
| Voltage drop Ud, maximum | 0.5 V | 
| Current leakage Ir | 0.5 mA | 
| Voltage, Utilisation category DC12 | 24 VDC | 
| Current, Utilisation category DC12 | 0.25 A | 
| Voltage, Utilisation category DC13 | 24 VDC | 
| Current, Utilisation category DC13 | 0.25 A | 
Electrical data - Diagnostic output
| Operating current | 150 mA | 
| Versions | p-type | 
| Voltage drop Ud, maximum | 5 V | 
Electrical data - Electromagnetic compatibility (EMC)
| Interfering radiation | IEC 61000-6-4 | 
| EMC rating | IEC 61000-6-2 | 
Pin assignment
| PIN 1 | 1A1 Ue: (1) | 
| PIN 2 | X1 Safety input 1 | 
| PIN 3 | A2 GND | 
| PIN 4 | Y1 Safety output 1 | 
| PIN 5 | SD serial diagnostic output | 
| PIN 6 | X2 Safety input 2 | 
| PIN 7 | Y2 Safety output 2 | 
| PIN 8 | IN serial diagnostic input | 
Scope of delivery
| Included in delivery | Actuators must be ordered separately. | 
Accessory
| Recommendation (actuator) | CST 34-S-2 CST 34-S-3 CST 180-1 CST 180-2 CST 34-S-1 | 
| Recommended safety switchgear | PROTECT PSC1 SRB-E-301ST SRB-E-201LC | 
Notes
| Note (General) | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 0.5 ms. Short-circuit recognition by the evaluation is not necessary. | 
 
                



 
                                         
                                         
                                         
                                         
                                         
                                         
                                 
                                 
                                 
                                 
                                
 
                   
                   
                  